Experimental Study on Site-Built Reinforcing Rib Composite Wall under Low Cyclic Loading
Abstract:
Site-built reinforcing rib composite wall is a kind of composite wall composed of reinforced concrete rib columns, rib beams and filling masonry. This paper mainly introduces the failure process and failure mechanism of this kind of composite wall under low cyclic loading. The wall has a good seismic performance and can be suitable for rural building structure.