Experimental Study on Site-Built Reinforcing Rib Composite Wall under Low Cyclic Loading

Article Preview

Abstract:

Site-built reinforcing rib composite wall is a kind of composite wall composed of reinforced concrete rib columns, rib beams and filling masonry. This paper mainly introduces the failure process and failure mechanism of this kind of composite wall under low cyclic loading. The wall has a good seismic performance and can be suitable for rural building structure.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

867-872

Citation:

Online since:

December 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Wu Huige, Luo Huilai, and Chen Huiqin , Scientific and Technological Information, p.338, vol. 10, ( 2011 in Chinese).

Google Scholar

[2] Sun Weidong, Experimental Study of Composed Wall with Site Laying Reinforcing Rib under the Effect of Vertical Load, Electric Technology and Civil Engineering. Vol 5. 3181-3185(2012).

DOI: 10.4028/www.scientific.net/amm.501-504.954

Google Scholar