Study on Determination of Best Window-Wall Ratio of Office Building in Cold Area

Article Preview

Abstract:

The cooling and heating load caused by the heat transfer of the window is significantly greater than that caused by the heat transfer of wall because of the large heat transfer coefficient of the window. At the same time, the sun radiate heat through the window into indoor can increase the cooling load and decrease the heating load; the natural lighting enhances, and the lighting energy consumption decreases because of entering sunlight. The paper took a low energy consumption office building in the northern China for example, synthetically analyzed the cooling energy consumption, heating energy consumption and lighting energy consumption of every orientation under the condition of lighting control or no lighting control. The results show that comparing with no lighting control, the energy consumption with lighting control is less. When using lighting control, the best WWR of south, north, east, west are 0.35, 0.3, 0.3, 0.25, respectively; then the building energy saving rate is 8.2%.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

209-216

Citation:

Online since:

December 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Zhang Wei, Zhang Zhigang, Liu Xianchong, Invertigation and analysis of energy consumption of public buildings in Tianjin city, J. GAS & HEAT. 5(2011) 24-26.

Google Scholar

[2] Li Zhisheng, Zhang Guoqiang, Li Dongmei, Mei Sheng, Liu Xuhong, Li Lixin, Energy consumption features for large-scale public office buildings in greater Guangzhou, P. R. China, J. Journal of Chongqing Jianzhu University. 5(2008) 112-117.

Google Scholar

[3] Wang Yuan, Wei Qingpeng, Xue Zhifeng, Jiang Yi, The energy saving consultation of the large-scale public building( third), J. Construction Science and Technology. 2(2007) 17-19.

Google Scholar

[4] EIA. Energy end-use intensities in commercial buildings. Energy Information Administration US Department of Energy, Washington, (1994).

DOI: 10.2172/10185769

Google Scholar

[5] Jin Zhaofen, Zhu Yingxin, Building Environment, third ed., China Building Industry Press, Beijing, (2001).

Google Scholar

[6] Tang Keyue, Li Deying, Gao Yan, Influence analysis of outer wall types acts on the relationship between the total energy consumption and the ratio of window to wall, J.  Construction Conserves Energy. 10(2008) 21-23.

Google Scholar

[7] Liu Maihua, Xi Lan, Affection of window-wall ratio on energy consumption, J. GUANGXI JOURNAL OF LIGHT INDUSTRY, 8(2011) 44-48.

Google Scholar

[8] Athanassios Tzempelikos, Andreas k. Athienitis, The impact of shading design and control on building cooling and lighting demand, J . Solar Energy, 3(2007) 369-382.

DOI: 10.1016/j.solener.2006.06.015

Google Scholar

[9] Bullow-Hube, H, The effect of glazing type and size on annual heating and cooling demand for Swedish offices, J. Building and Environment, 40(2005)51-61.

Google Scholar

[10] Information on http: /apps1. eere. energy. gov/buildings/energyplus/openstudio. cfm.

Google Scholar

[11] BSR/ASHRAE Standard 140P, Standard Method of Test of the Evaluation of Building Energy Analysis Computer Programs, ASHRAE, First Public Review Draft, Atlanta, Georgia, (2000).

Google Scholar

[12] B.H. Bland, Conduction tests for the validation of dynamic thermal models of buildings, BEPAC Technical Note 93/1, (1993).

Google Scholar

[13] Hartleb Puleo SB, Leslie RP, Some effects of sequential experience of windows on human response, J. Journal of the Illuminating Engineering Society, 1(1991)91-93.

DOI: 10.1080/00994480.1991.10748928

Google Scholar

[14] Collins Belinda Lowenhaupt. In: Windows and people: a literature survey. Psychological reaction to environments with and without windows. National Buresu of Standards, Buildings Science Series, Washington, DC: NBS, (1975).

Google Scholar

[15] LEED 2009 FOR COMMERCIAL INTERIORS, S. (2008)59-60.

Google Scholar