A Reactive Power Generator Based on Voltage Source Inverter

Article Preview

Abstract:

With the application of large scale nonlinear load in power systems, lots of harmonic are produced, causing the total power factor to decrease. Therefore, it needs to compensate the reactive power of power systems. The disadvantages of the widely applied static var compensator are that the size of the compensator is too large, and the control ability is poor when the capacity of power systems is small. So a reactive power generator based on voltage source inverter is proposed in this paper. The reactive power generator takes series connection of IGBTs as the main circuit structure, the inverter as core and DSP as controller. The close loop framework consists of human-computer interaction, measurements and feedback control. The inverter is controlled by a digital PI close loop controller to feed a phase adjustable current to power systems to compensate reactive power. The system’s structure is simple, the control is flexible, and the size is small. The test results show that the response of this reactive power generator is quick, and it can compensate the power factor to be 1 which means that it has good effect of static reactive compensation.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

432-437

Citation:

Online since:

December 2012

Authors:

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Wang Zhao-an. The reactive power compensation and harmonic control[M]. Beijing:China Machine Press,(2006).

Google Scholar

[2] CK Lee, JSK Leung, SYR Hui. Circuit-level comparison of STATCOM technologies[J]. IEEE Trans on Power Electronics, 2003, 18(4): 1084—1092.

DOI: 10.1109/tpel.2003.813771

Google Scholar

[3] Sun J, Czarkowski D, Zabar Z. Voltage flicker mitigation using PWM-based distribution STATCOM[C]. 2002 IEEE Power Engineering Society Summer Meeting, 2002, 1: 616- 621.

DOI: 10.1109/pess.2002.1043313

Google Scholar

[4] Su Chun, Ma-Xiaojun. The Experimenyal Research on Statcom to Mitigate the Voltage SAG under load disturbance[J]. Proceeding of the CSEE, 1999, 19( 9) : 46- 49.

Google Scholar

[5] Sun-Yuanzhang, Wang-Zhifang. The Effect of SVC on the Voltage Stability[J]. Proceeding of the CSEE, 1997,17(6): 373-376.

Google Scholar

[6] Li Chun,Jiang Qirong,Xiu Lincheng.Reactive power control of STATCOM using PID auto—tuning technique and fuzzy set[J]. Control Theory and Applications, 2000, 17(6): 856~860.

Google Scholar

[7] Chen Xian-ming, Xu-Hepin. ±500kvar. The development of Static reactive power generator[J]. Automation of Power Systems. 2001. 25(24): 53-57.

Google Scholar

[8] Shen D, Lehn P W. Modeling, Analysis and Control of a Current Source Inverter-Based STATCOM. IEEE Trans on Power Delivery, 2002, (1): 248-253.

DOI: 10.1109/61.974214

Google Scholar

[9] Liu-Peiguo, Dai ke, Xiong jian. A Current Control Technology of Three-phase VSC based on DSP[J]. Power Electronics, (2003).

Google Scholar