Optimal Simulation on the Variable Load for an Ultra-Supercritical Boiler

Article Preview

Abstract:

The characteristics of flow, combustion, heat transfer and NOx emission were numerically investigated under the different load operation for an 1000MW ultra-supercritical swirling opposed coal-fired utility boiler.The simulated results agree well with the measured values. The results show that compared with 100% load all 6 mills in service, 70% load 4 mills is running, pulverized coal burnout rate increase, fly ash carbon content is reduced and NOx emissions reduced greatly, the flue gas temperature is reduced greatly chamber exports, which helps reduce panel superheater hang the tendency of slag, wall maximum thermal load obvious move down to middle burner and the lower between the burner area. The direction information can be provided for mastering the combustion characteristics of this type of boiler, adjusting and optimizing the operation by the research result.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

1679-1683

Citation:

Online since:

February 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Korytnyi E, Saveliev R, Perelman M, Chudnovsky B. Fuel, 2009, 88: 9-18.

Google Scholar

[2] Fang Qingyan, Wang Huajian. Chen Gang. Proceedings of the CSEE. 2011, 31(5): 1-6.

Google Scholar