Discuss on Post Combustion Characteristics of the 116MW Circulating Fluidized Bed Hot Water Boiler

Article Preview

Abstract:

116MW circulating fluidized bed hot water boiler performance testing was carried out that found that burning high volatile lignite had post combustion phenomenon of separator yet. The phenomenon of post-combustion research results show that flue gas outlet temperature rise of the separation can be significantly reduced by adjusting the twelve wind ratio; Increasing coal-fired granularity which was able to reduce the separator post combustion phenomenon; Moderate post combustion of separation was able to improve boiler efficiency and reduce N2O. These results can provide guidance for improving boiler operation technology and improving the boiler design standard.