Electrochemical Evaluation Method for Soil Corrosion Properties in Grid Substation

Article Preview

Abstract:

Soil corrosion is the main reason of corrosion failure for substation grounding grids. To explore electrochemical evaluation method for soil corrosion of substation grounding grids would effectively ensure the safe operation of power grids. This paper discussed the main several kinds of soil corrosive electrochemical research methods and application. These methods played an important role on researching soil corrosion mechanism, soil corrosivity and corrosion behavior.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

811-814

Citation:

Online since:

February 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] P. Pernice, M. Arpaia,A. Costantini. Steel corrosion rate in soils by a. c and d. c electrochemical methods[J]. Materials Chemistry and Physics, 1990, 26(3): 323-330.

DOI: 10.1016/0254-0584(90)90020-b

Google Scholar

[2] Junhua Dong, Enhou Han, Wei Ke. Introduction to atmospheric corrosion research in China[J]. Science and Technology of Advanced Materials, 2007, 8(7): 559-565.

DOI: 10.1016/j.stam.2007.08.010

Google Scholar

[3] Paul E des Rosiers. Evaluation of technology for wastes and soils contaminated with dioxins, furans, and related substances[J]. Journal of Hazardous Materials, 1987, 14(1): 119-133.

DOI: 10.1016/0304-3894(87)87009-7

Google Scholar

[4] S. P Theocharopoulos, I. K Mitsios, I Arvanitoyannis. Traceablity of environment soil measurements[J]. TrAC Trends in Analytical Chemistry, 2004, 23(3): 237-251.

DOI: 10.1016/s0165-9936(04)00317-6

Google Scholar

[5] Werner Gerwin, Roland Baumhauer. Effect of soil parameters on the corrosion of archaeological metal finds[J]. Geoderma, 2000, 96(1): 63-80.

DOI: 10.1016/s0016-7061(00)00004-5

Google Scholar

[6] H.A. Abdalla. Assessment of damages and repair of antenna tower concrete foundations[J]. Construction and Building Materials, 2002, 16(8): 527-534.

DOI: 10.1016/s0950-0618(02)00028-4

Google Scholar

[7] Fan Yang, Baoyou Shi, Junnong Gu. Morphological and physicochemical characteristics of iron corrosion scales formed under different water source histories in a drinking water distribution system[J]. Water Research, 2012, 46(16): 5423-5433.

DOI: 10.1016/j.watres.2012.07.031

Google Scholar

[8] Kathryn H. Winnebeck. An abbreviated alternatives assessment process for product designers: a children's furniture manufacturing case study[J]. Journal of Cleaner Production, 2011, 19(5): 464-476.

DOI: 10.1016/j.jclepro.2010.10.008

Google Scholar

[9] N. Ghedini, I. Ozga, A. Bonazza, M. Dilillo. Atmospheric aerosol monitoring as a strategy for the preventive conservation of urban monumental heritage: The Florence Baptistery[J]. Atmospheric Environment, 2011, 45(33): 5979-5987.

DOI: 10.1016/j.atmosenv.2011.08.001

Google Scholar

[10] Wang Wen-he, Shen Shi-ming, Yu Xiao-chun. Review on research methods of soil corrosion for buried pipeline steels[J]. Journal of Nanjing University of Technology, 2008, 30(4): 105-110.

Google Scholar

[11] Dong Chaofang, Li Xiaogang, Wu Junwei. Review in Experimentation and Data Processing of Soil Corrosion[J]. Corrosion Science and Protection Technology, 2003, 15(3): 154-160.

Google Scholar