Rapid Determination of Sulfite by Flow Injection Analysis Based on Fuchsin′s Addition

Article Preview

Abstract:

A rapid spectrophotometric method for flow injection determination of sulfite in tan wastewater is described. The proposed method was based on the addition reaction of sulfite with fuchsin in Na2B4O7-NaOH medium. The optimum conditions allow a linear calibration range of 0.01-1.20 μg ml-1 SO32-. The detection limit is 0.0023μg ml-1 (S/N=3), and the relative standard deviation for night replicate measurements is 1.1% for 0.5μg ml-1 of sulfite. The sampling rate is 60 samples h-1. The procedure has been applied to the determination of sulfite in tan wastewater. The results were in good agreement with those obtained by pararosaniline method.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

950-953

Citation:

Online since:

February 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] N. Sarlak, M. Anizadeh, Simultaneous kinetic spectrophotometric determination of sulfide and sulfite ions by using an optode and the partial least squares (PLS) regression, Sens. Actuators, B: Chemical, 160(2011) 644-649.

DOI: 10.1016/j.snb.2011.08.042

Google Scholar

[2] P. D. Tzanavaras, E. Thiakouli, D. G. Themelis, Hybrid sequential injection–flow injection manifold for the spectrophotometric determination of total sulfite in wines using o-phthalaldehyde and gas-diffusion, Talanta 77( 2009)1614-1619.

DOI: 10.1016/j.talanta.2008.09.051

Google Scholar

[3] T. García, E. Casero, E. Lorenzo, F. Pariente, Electrochemical sensor for sulfite determination based on iron hexacyanoferrate film modified electrodes, Sens. Actuators, B: Chemical, 106( 2005) 803-809.

DOI: 10.1016/j.snb.2004.09.033

Google Scholar

[4] M. V. Navarrro, M. R. Payán, M. A. B. López, Rut Fernández-Torres, M. Callejón Mochón, Rapid flow injection method for the determination of sulfite in wine using the permanganate–luminol luminescence system, Talanta 82(2010)2003-(2006).

DOI: 10.1016/j.talanta.2010.08.021

Google Scholar

[5] X. F. Yang, X. Q. Guo, Y.B. Zhao, Novel spectrofluorimetric method for the determination of sulfite with rhodamine B hydrazide in a micellar medium , Anal. Chim. Acta 456 (2002) 121-128.

DOI: 10.1016/s0003-2670(02)00005-3

Google Scholar

[6] Ümmihan T. Yilmaz, Güler Somer, Determination of trace sulfite by direct and indirect methods using differential pulse polarography , Anal. Chim. Acta 603(2007)30-35.

DOI: 10.1016/j.aca.2007.09.035

Google Scholar

[7] S. L. Ohira, K. Toda, Ion chromatographic measurement of sulfide, methanethiolate, sulfite and sulfate in aqueous and air samples, J. Chromatogr. A, 1121(2006) 280-284.

DOI: 10.1016/j.chroma.2006.05.074

Google Scholar