Study on the Influence of Gravity Factor on Parametric Resonance of Pipe Conveying Fluid
Abstract:
The averaging method has been applied to calculate the critical conditions of parametric resonance instability of the first order mode shape of clamped-clamped and pinned-pinned pipes conveying fluid. The influence of gravity factor on parametric resonance of pipe conveying fluid, with different supporting forms and different flow velocity, has been studied based on the comparison results of gravity factor being considered and neglected. It is concluded that gravity factor has a greater influence on parametric resonance region of pinned-pinned pipe than the one of clamped-clamped pipe, and, at a higher flow velocity, gravity factor is more influential to both pinned-pinned pipe and clamped- clamped one.