Development for Cyclic Detection Laboratory of Transmission and Distribution State Maintenance and Test Equipment

Article Preview

Abstract:

Power production department is paying more and more attention to the test results of high voltage test instrument and equipment as the power construction is vigorously developing. Currently, the metrological verification of high voltage test instrument is mainly conducted by metrological department such as provincial Electric Power Research Institute (EPRI) of the Power Grid, and standard appliances of measurement are stored in regular laboratory condition and inspection method of them is bottom-to-top periodic inspection by users, which has the disadvantage of inconvenient inspection. The cyclic detection laboratory developed in this paper, which can support comprehensive calibration and on-site detection for the main functions of mainstream high voltage test instruments of the market, is designed aiming at the requirements of cyclic detection for high voltage test instrument of power system. Operating principles and core technologies of the developed detection equipment are detailed introduced in this paper. By using the developed laboratory, performances of test instruments can be effectively assessed, diverse needs of metrological detection for high voltage test instrument of power system can be further met, and operation safety of power system and economic benefit of power industry can be improved as well as on-site metrological detection capacity being strengthened.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

957-960

Citation:

Online since:

February 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] ZHANG Jun, LEI Min, XIANG Qiong et al. Research on Calibration Device for on-load Tap-changer Tester Based on Power MOSFET[J]. Electrical Measurement & Instrumentation, 2009, 46(4): 53-57.

Google Scholar

[2] ZHANG Jun, LEI Min, WANG Si-qi et al. Research on Standard Device for Transmission Lines Power Frequency Parameters Tester[J]. Electrical Measurement & Instrumentation, 2011, 48(10): 25-29.

Google Scholar

[3] XU Zi-li, LI Qian, HU Hao-liang et al. Research on Verification Equipment of DC Electrical Energy Meter for Electric Vehicle Charger[J]. Electrical Measurement & Instrumentation, 2011, 48(12): 65-69.

Google Scholar

[4] ZHANG Jun, BAO Yu-shu, ZHANG Ying-xing et al. Development of Standard Device for Resistive Current Tester for Zinc Oxide Surge Arrester[J]. Electrical Measurement & Instrumentation, 2010, 47(4): 30-34, 4.

Google Scholar

[5] ZHAO Xiu-min, ZHAO Yi-tao, HAN Hai-zhou et al. Research on the Whole Certification of the Locale Device Used to Test Current Transformer[J]. Electrical Measurement & Instrumentation, 2012, 49(7): 37-39, 43.

Google Scholar