Abstract:

This paper proposes a bi-stable permanent magnetic actuator (PMA) for medium voltage vacuum circuit breaker. The structure of the proposed PMA is discussed and the optimization of the structure is carried out. The model of finite element analysis (FEA) is constructed where the flux distributions, electromagnetic force under different structure parameters are analyzed. The feasibility and correctness of the PMA are verified by the FEA simulation results and the optimal size for movable plunger and stationary iron ring is obtained.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

20-26

Citation:

Online since:

March 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] CIGRE SC13: High Voltage Circuit Breaker Reliability Data for Use in System Reliability Studies, CIGRE Publication, Paris (1991).

Google Scholar

[2] R. G. Garzon: High Voltage Circuit Breakers Design and Applications, Marcel Dekker, Inc., second edition, New York (2002).

Google Scholar

[3] S. A. Ruhland: Vacuum Circuit Breaker with Asymmetrical Actuator, Transmission and Distribution Conference and Exhibition: Asia Pacific, IEEE/PES, Yokohama (2002), pp.909-913.

DOI: 10.1109/tdc.2002.1177597

Google Scholar

[4] J. H. Kang, S. Y. Kwak, R. E. Kim, H. K. Jung: The Optimal Design and Dynamic Characteristics Analysis of Electric Actuator for 170kV/50kA VCB Based on Three-link Structure, XXIIIrd Int. Symp. Discharges and Electrical Insulation in Vacuum, Bucharest (2008).

DOI: 10.1109/deiv.2008.4676748

Google Scholar

[5] K. Kato, Y. Matsumoto, K. Matsuo, M. Homma: The Development of Low-surge-type VCB with a Balanced-type Magnetic Actuator, XXIInd Int. Symp. Discharges and Electrical Insulation in Vacuum, Matsue (2006).

DOI: 10.1109/deiv.2006.357339

Google Scholar

[6] Z. Li, L. A. Renforth, D. W. Auckland and B. Varlow: Computer Aided Optimal Design of Magmetic Actuator for Autorecloser Application, IEE Conf. Pub. , (1998), pp.80-85.

DOI: 10.1049/ip-epa:20000559

Google Scholar

[7] A. J. W. Lammers, P. P. Leufkens, G. C. Schoonenberg: MV Vacuum Switchgear Based on Magnetic Actuators, IEE Conf. Pub. , (1998), pp.86-90.

Google Scholar

[8] B. A. R. Mckean: Magnetics & Vacuum – The Perfect Match, Fifth International Conference on Trends in Distribution Switchgear (1998).

DOI: 10.1049/cp:19980744

Google Scholar

[9] W. Li, C. Fang, L. Zhou, J. Wang: Simulation and Testing of Operating Charactersitic of 27.5kV Vacuum Circuit Breaker with Permanent Magnetci Actuator, XXIII-rd Int. Symp. Discharges and Electrical Insulation in Vacuum, Bucharest (2008).

DOI: 10.1109/deiv.2008.4676735

Google Scholar

[10] S. Ma, J. Wang: Research and Design of Permanent Magnetic Actuator for High Voltage Vacuum Circuit Breaker, XXth Int. Symp. Discharges and Electrical Insulation in Vacuum, Tours (2002).

DOI: 10.1109/isdeiv.2002.1027415

Google Scholar

[11] K. N. Park, J. W. Son, S. C. Hahn: Dynamic Characteristic Analysis of Permanent Magnetic Actuators Coupled Electromagnetic-mechanical Finite Element Method, 2010 International Conference on Electrical Machines and Systems, Incheon Korean (2010), pp.1706-1709.

Google Scholar

[12] Z. Cai, S. Ma, J. Wang: An Approach of Improve Permanent Magnetic Actuator of Vacuum Circuit Breaker, XXIII-rd Int. Symp. Discharges and Electrical Insulation in Vacuum, Bucharest (2008).

DOI: 10.1109/deiv.2008.4676745

Google Scholar