A Simple Model Used to Predict the Thermal Performance of Flat-Plate Closed-Loop Pulsating Heat Pipe

Article Preview

Abstract:

The thermal performance Rov of Flat-Plate Closed-Loop Pulsating Heat Pipe(FCLPHP) are effected by several elements such as the heat load Q, the tilt angle θ and the filling ratio F, they are interacted each other. In order to predict the effect of Q and θ on the thermal performance at locations Q and θ other than the experimental data conditions, and to study the relationship among the Rov, Q and θ in the range of the experimental data, we need a fitted regression model to estimate the function relationship that describes the data. The postulated depends on the range of the regression variables encountered in the data. In this paper, a simple model was developed. Since the coefficients in the model have been estimated from the experimental data, studies were carried out on an experimental set-up. FC72 was employed as working fluid. Method of least squares was used for building the model. By using the model, effects of the heat load and the tilt angle on the thermal performance of FCLPHP were discussed. It was found that the tilt angle had minimum value in a certain heat load in the experimental range (θ=30° -70°), and it increases with the increase of heat load. A sensitivity analysis was done with the model.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

7-12

Citation:

Online since:

April 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] H. Akachi, U.S. Patent No. 4921041, 1990.

Google Scholar

[2] H. Akachi, F. Polasek, P. Stulc, Pulsating heat pipes, Proceedings of the 5th International Heat Pipe Symposium, Melbourne, Australia: Pergamon Press Ltd, (1996) 208-217.

Google Scholar

[3] B. Holley, A. Faghri, Analysis of pulsating heat pipe with capillary wick and varying channel diameter, Int. J. of Heat and Mass Transfer, 48 (2005) 2635 - 2651.

DOI: 10.1016/j.ijheatmasstransfer.2005.01.013

Google Scholar

[4] S. Khandekar, N. Dollinger, M. Groll, Understanding operational regimes of closed loop pulsating heat pipes: an experimental study, Applied Thermal Engineering, 23 (2003) 707 – 719.

DOI: 10.1016/s1359-4311(02)00237-5

Google Scholar

[5] Y. Lin, S. Kang, T. Wu, Fabrication of polydimethylsiloxane (PDMS) pulsating heat pipe, Applied Thermal Engineering, 29 (2009) 573 – 580.

DOI: 10.1016/j.applthermaleng.2008.03.028

Google Scholar

[6] G. Xu, S. Ling, M. Vogel, T. Katoh, Thermal characterization of pulsating heat pipe, Proceedings of the 10th Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronics Systems, p.552–556, IEEE, San Diego, Calif, USA, 2006.

DOI: 10.1109/itherm.2006.1645393

Google Scholar

[7] H. B. Ma, M. A. Hanlon, C. L. Chen, An investigation of oscillating motions in a miniature pulsating heat pipe, Microfluid Nanofluid, 2 (2006) 171 – 179.

DOI: 10.1007/s10404-005-0061-8

Google Scholar

[8] W. Qu, H. B. Ma, Theoretical analysis of startup of a pulsating heat pipe, Int. J. Heat Mass Transfer, 50 (2007) 2309 – 2316.

DOI: 10.1016/j.ijheatmasstransfer.2006.10.043

Google Scholar

[9] ISO/IEC GUIDE 98-3:2008(E), Uncertain of Measurement-Part 3:Guide to the expression of uncertainty in measurement (GUM:1995)11-18.

Google Scholar

[10] Q. P. Wu, R. G. Xu, H. Zhang, Y. Z. Li, Heat Transfer of Closed Flat-plat Loop Pulsating Heat Pipe in Start-up Stage, In: Proceedings of 2011 International Conference on Materials for Renewable Energy and Environment, (2011) 864-868.

DOI: 10.1109/icmree.2011.5930941

Google Scholar

[11] Q. P. Wu, R. X. Wang, Y. J. Li, R. G. Xu, and Y. Z. Li, Influence of Working Fluid Thermophysical Property on Thermal Performance of Flat-Plate Closed Loop Pulsating Heat Pipe, Appl. Mechanics and Materials. 130 (2012) 130-134.

DOI: 10.4028/www.scientific.net/amm.130-134.1799

Google Scholar

[12] S. Khandekar, M. Schneider, Thermofluid dynamic study of flat plate closed loop pulsating heat pipes, Microscale Thermophysical Engineering, 6 (2002) 303-317.

DOI: 10.1080/10893950290098340

Google Scholar