Abstract:

This paper presents a portable blood detection system on the basis of dry-type chemical method. Controlled by TM320VC5509A, a high-precision Digital Signal Processor, provided light source by line spot semiconductor laser (LD), converted between light and electricity by photocoupler, the system can fulfill the conventional detection and measurement of blood cells parameters. As for the stability of the system, the test results showed that the relative standard deviation of the parameters of the blood cells were all below 1.7%. The contrast experiment on Sysmex XT-1800i showed that with hematocrit (HCT), hemoglobin (HGB), lymphocytes and moncytes (LM), granulocytes (GRAN), platelets (PLT) and white blood cell (WBC) as contrast items, the correlation coefficients of the system were 0.9910.9720.9520.9860.979 and 0.985 respectively. The volume and time measurements of the system were designed as (25×20×10) cm3 and 60s. The system can fulfill some functions such as indicating records, seeking information and deleting. The system will have a wide application prospect in rapid test of blood in field and emergency examination.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

1620-1626

Citation:

Online since:

June 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Stephen C. Wardlaw, MD, Robert A. Levine, MD. Quantitative Buffy Coat Analysis. JAMA, 1983, 249:617-620.

Google Scholar

[2] Robert A, Levine, Guilford, Stephen C. Quantification of fibrinogen in whole blood samples contained in a tube using a float to separate materials [P]. United States Patent:5137832, (1991)

Google Scholar

[3] Jiang Jingting, Zhou Keqin, Xie Yanlong, etc. Dry type blood cell analyzer and its performance evaluation [J]. Information Guide for Clinical Laboratory, 1995,2(1):25-27

Google Scholar

[4] Agranoff BW, Vallee BL, Waugh DF. Centrifugal subfractionation of polymorphonuclear leukocytes, Lymphocytes and Erythrocyte [J]. Blood. 1954 Aug; 9(8):804-9.

DOI: 10.1182/blood.v9.8.804.804

Google Scholar

[5] Wang Xingzhen, Zhu Shenghua, Liu Qing, Field evaluation of QBC technique and fluorochrome stain applied to rapid diagnosis of vivax malaria . ⅠEffectivenesss of the "QBC" technique for diagnosing vivax malaria in field work [J]. Journal of Practical Parasitic Diseases, 1995,3(1):16-21

Google Scholar

[6] Robert A. Levine, Stephen C. Wardlaw, Method for measuring hemoglobin [P]. United States Patent: 4875364, (1989)

Google Scholar

[7] Chen Zulin, Xu Zhengrui, Nie Huifang. Experimental study on absorption laws of the blood components to light [J]. Chinese Journal of Lasers, 1994, 21(1):77-80

Google Scholar

[8] Hu Jianhua, Zhou Jinsheng. Research and Development of the blood cell analyzer [J]. Medical Equipment,1999,vol(2): 2-3

Google Scholar