Optimal Sensor Placement Method for Gantry Crane SHM System

Article Preview

Abstract:

The choice of the number and location of sensors in the structure is the foundation of cranes structural health monitoring, which has major influence on the monitoring results. This paper taking a gantry crane as a SHM research object, uses optimal sensor placement based on Finite Element Method, the stress concentration points could be drawn by the FEM calculation results. This method carry out dynamic load stress analysis for the structure with virtual prototype, which make up for the lack of static analysis; compared with the type test methods, not only reduce the test cost, but also more flexible, and break through the restrictions of all types of extreme conditions. This method makes the sensor data obtained more realistically reflects the crane structure condition; provides reliable data support for crane safety monitoring and safety evaluation. The promotion of this method will provide important technical support for the development of the crane SHM.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

697-702

Citation:

Online since:

June 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Guratzsch RF, Mahadevan S. Sensor placement design for SHM under uncertainty. 3rd European Workshop on Structural Health Monitoring 2006, July 5, 2006 - July 7, 2006. Granada, Spain: DEStech Publications Inc., 2006:1168-75.

DOI: 10.2514/6.2006-7034

Google Scholar

[2] Guratzsch RF, Mahadevan S. Probabilistic optimization of sensor placement. 25th Conference and Exposition on Structural Dynamics 2007, IMAC-XXV, February 19, 2007 - February 22, 2007. Orlando, FL, United states: Springer New York, 2007:Society for Experimental Mechanics (SEM).

Google Scholar

[3] Guratzsch RF, Mahadevan S. Sensor placement for aerospace vehicle health monitoring systems. Earth and Space 2006 - 10th Biennial International Conference on Engineering, Construction, and Operations in Challenging Environments, March 5, 2006 - March 8, 2006. League City/Houston, TX, United states: American Society of Civil Engineers, 2006:2.

DOI: 10.1061/40830(188)2

Google Scholar

[4] Lytle AM, Saidi KS, Bostelman RV, Stone WC, Scott NA. Adapting a teleoperated device for autonomous control using three-dimensional positioning sensors: Experiences with the NIST RoboCrane. : Elsevier, 2004:101-18.

DOI: 10.1016/j.autcon.2003.08.009

Google Scholar

[5] Murayama H, Igawa H, Omichi K, MacHijima Y. Application of distributed sensing with longlength FBG to structural health monitoring. 9th International Conference on Optical Communications and Networks, ICOCN 2010, October 24, 2010 - October 27, 2010. Nanjing, China: Institution of Engineering and Technology, 2010:18-24.

DOI: 10.1049/cp.2010.1143

Google Scholar

[6] Ma Z, Zhang K, Chen J. Application of optimal sensor placement algorithms for vibration characteristics analysis of power house in hydropower station. Dalian Ligong Daxue Xuebao/Journal of Dalian University of Technology. 2006;46(2):262-6.

Google Scholar

[7] Doggett WR, King BD, Jones TC, Dorsey JT, Mikulas MM. Design and field test of a mass efficient crane for lunar payload handling and inspection: the lunar surface manipulation system. Space 2008 Conference, September 9, 2008 - September 11, 2008. San Diego, CA, United states: American Institute of Aeronautics and Astronautics Inc., 2008.

DOI: 10.2514/6.2008-7635

Google Scholar

[8] Murayama H, Kageyama K, Ohara K, Uzawa K, Kanai M, Igawa H. Distributed strain measurement of welded tubular joint with long gauge FBG. 19th International Conference on Optical Fibre Sensors, April 15, 2008 - April 18, 2008. Perth, WA, Australia: SPIE, 2008:University of Western Australia; Optical and Biomedical Engineering Laboratory (OBEL).

DOI: 10.1117/12.786182

Google Scholar

[9] Sun W, Yan S, Qi B, Han Y, Zhang Y. FEM analysis in anti-fatigue character of steel crane-beam reinforced by CFRP. Shenyang Jianzhu Daxue Xuebao (Ziran Kexue Ban)/Journal of Shenyang Jianzhu University (Natural Science). 2007;23(5):728-31.

DOI: 10.18057/ijasc.2013.9.2.3

Google Scholar

[10] Li B, Wang D, Wang F, Ni YQ. High quality sensor placement for SHM systems: Refocusing on application demands. IEEE INFOCOM 2010, March 14, 2010 - March 19, 2010. San Diego, CA, United states: Institute of Electrical and Electronics Engineers Inc., 2010.

DOI: 10.1109/infcom.2010.5462159

Google Scholar

[11] Malinowski P, Wandowski T, Ostachowicz W. Investigation of sensor placement in Lamb wave-based SHM method. 2nd International Conference on Smart Diagnostics of Structures, November 14, 2011 - November 16, 2011. Cracow, Poland: Trans Tech Publications Ltd, 2012:174-83.

DOI: 10.4028/www.scientific.net/kem.518.174

Google Scholar

[12] Kammer DC, Peck JA. Mass-weighting methods for sensor placement using sensor set expansion techniques. Mech Syst Signal Pr. 2008;22(7):1515-25.

DOI: 10.1016/j.ymssp.2008.01.002

Google Scholar

[13] Zhu Z, Zhang Y, Zeng C, Xiong Z. Preliminary investigation on embedding FBG fibre within AA6061 matrices by ultrasonic welding. 2010 International Conference on Robotic Welding, Intelligence and Automation, RWIA'2010, October 14, 2010 - October 16, 2010. Shanghai, China: Springer Verlag, 2011:375-81.

DOI: 10.1007/978-3-642-19959-2_46

Google Scholar

[14] Kozien MS, Wiciak J. Reduction of structural noise inside crane cage by piezoelectric actuators - FEM simulation. Archives of Acoustics. 2008;33(4):643-52.

Google Scholar

[15] Guratzsch RF, Mahadevan S, Pettit CL, Derriso MM. Sensor placement optimization for shm systems under uncertainty. 46th AIAA/ASME/ASCE/AHS/ASC Structures, Structural Dynamics and Materials Conference, April 18, 2005 - April 21, 2005. Austin, TX, United states: American Inst. Aeronautics and Astronautics Inc., 2005:5182-8.

DOI: 10.2514/6.2005-2217

Google Scholar

[16] DePaso JM, Lynch PM. Sensors and sensor managers in intelligent control applied to vision based weld seam survey. Winter Annual Meeting of the American Society of Mechanical Engineers, Nov 8 - 13 1992. Anaheim, CA, USA: Publ by ASME, 1992:121-6.

Google Scholar

[17] Zhang Y, Zhao J, Yao J. Static structural finite-element analysis of tower crane based on FEM. IEEE 2nd International Conference on Computing, Control and Industrial Engineering, CCIE 2011, August 20, 2011 - August 21, 2011. Wuhan, China: IEEE Computer Society, 2011:220-3.

DOI: 10.1109/ccieng.2011.6008106

Google Scholar

[18] Richter-Trummer V, Tavares SMO, Peixoto DFC, et al. Welding monitoring using FBG sensors. 3rd International Conference on Advances and Trends in Engineering Materials and their Applications, AES-ATEMA'2009, July 6, 2009 - July 10, 2009. Montreal, QC, Canada: Advanced Engineering Solutions, 2009:73-9

Google Scholar