Improved Algorithm for Identification of Thévenin Equivalent Parameters for Voltage Stability Analysis

Article Preview

Abstract:

This paper proposes an improved algorithm for tracking the Thévenin equivalent parameters with local phasor measurements for voltage stability analysis. Estimation errors between the Thévenin equivalent voltage and impedance are mathematically formulated, and then used to correct the equivalent parameters with two subsequent measurements. This algorithm does not introduce any parameters drift problems and does not need a large data window to converge. A 2-bus test system, the IEEE 14-buses system and an actual 500kV grid system from China are used to test the proposed algorithm. Test results indicate that this algorithm is accurate, robust and fast for real time voltage stability monitoring and control.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

1141-1152

Citation:

Online since:

July 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] C. Rehtanz. Wide area monitoring and control for transmission capability enhancement. GIGRE, Paris, France, 2006.

Google Scholar

[2] C. W. Taylor, D. C. Erickson, K. E. Martin, et al. WACS-Wide-Area stability and voltage control system: R&D and online demonstration, Proc. IEEE 93(5) (2005) 892-906.

DOI: 10.1109/jproc.2005.846338

Google Scholar

[3] M. Zima, M. Larsson, P. Korba, C. Rehtanz, and G. Andersson. Design aspects for wide-area monitoring and control systems, Proc. IEEE 93(5) (2005) 980-996.

DOI: 10.1109/jproc.2005.846336

Google Scholar

[4] G. Verbic and F. Gubina. A new concept of voltage-collapse protection based on local phasors, IEEE Trans. Power Del. 19(2) (2004) 576–581.

DOI: 10.1109/tpwrd.2004.824763

Google Scholar

[5] M. Parniani and M. Vanouni. A fast local index for online estimation of closeness to loadability limit, IEEE Trans. Power Syst. 25(1) (2010) 584-585.

DOI: 10.1109/tpwrs.2009.2036460

Google Scholar

[6] K.Vu, M.M. Begovic, D. Novosel, and M. M. Saha. Use of local measurements to estimate voltage-stability margin, IEEE Trans. Power Syst. 14(3) (1999) 1029-1035.

DOI: 10.1109/59.780916

Google Scholar

[7] B. Milosevic and M. Begovic. Voltage-stability protection and control using a wide-area network of phasor measurements, IEEE Trans. Power Syst. 18(1) (2003) 121-127.

DOI: 10.1109/tpwrs.2002.805018

Google Scholar

[8] I. Smon, G. Verbic, and F. Gubina. Local voltage-stability index using Tellegen's theorem, IEEE Trans. Power Syst. 21(3) (2006) 1267-1275.

DOI: 10.1109/tpwrs.2006.876702

Google Scholar

[9] S. Corsi and M. Pozzi. A real-time EHV bus-bar indicator of local voltage instability, in Proc. IFAC Symp. Power Plants and Power Systems Control, Calgary, AB, Canada, Jun. 2006.

Google Scholar

[10] S. Corsi, G. N. Taranto. A real-time voltage instability identification algorithm based on local phasor measurements, IEEE Trans. Power Syst. 2008, 23(3) (2008) 1271-1279.

DOI: 10.1109/tpwrs.2008.922586

Google Scholar

[11] H. Sun and X. Zhou. An on-line voltage stability index of power system considering induction motor loads, Proceedings of the CSEE 26(6) (2006) 1-7.

Google Scholar

[12] W. Gu and Q. Wan. Linearized voltage stability index for wide-area voltage monitoring and control, Int. J. Elect. Power Energy Syst. 32(4) (2010) 333-336.

DOI: 10.1016/j.ijepes.2009.09.003

Google Scholar

[13] R. He, J. Ma, and D. J. Hill. Composite load modeling via measurement approach, IEEE Trans. Power Syst. 21(2) (2006) 663-672.

DOI: 10.1109/tpwrs.2006.873130

Google Scholar

[14] M. Glavic, T. Van Cutsem, Wide-area dection of voltage instability from synchronized phasor measurements. Part II: Simulation Results, IEEE Trans. Power Syst. 24(3) (2009) 1417-1425.

DOI: 10.1109/tpwrs.2009.2023272

Google Scholar

[15] C. A. Canizares, Voltage stability assessment: Concepts, practices and tools, IEEE/PES Power System Stability Subcommittee, Final Document, Tech. Rep., Aug. 2002.

Google Scholar

[16] M. Glavic, T. Van Cutsem. Wide-area dection of voltage instability from synchronized phasor measurements. Part I: Principle, IEEE Trans. Power Syst. 24(3) (2009) 1408-1416.

DOI: 10.1109/tpwrs.2009.2023271

Google Scholar