Design of Sensor for Detecting Corona Discharge Signal in Specific Band

Article Preview

Abstract:

Corona discharge signal from the high-voltage transmission line exhibits unique characteristics compared to other radiation signals, which include wide distribution of frequency, small signal amplitude and strong randomness. The properties of frequency distribution of corona discharge signal and noise were tested in the range of 0 MHz-1.5 GHz to obtain the most beneficial detecting band. Based on the characteristics and properties, a high-gain helical antenna with the center frequency of 250 MHz was designed, and the performance of the antenna was tested. The corona discharge signal from 550 kV extra-high-voltage power line at the distance of about 320 meters was successfully detected by the helical antenna. The results showed that this design achieves the expected requirements and have a good practical performance. The design of antenna may provide supports for the further research on remote detection system of corona discharge signal.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

158-162

Citation:

Online since:

July 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Wang Bao-Quan, Xie Hui-Chun, Fang Liang. Electromagnetic environment and corona control measures of UHV substation. High-voltage Engineering. 2010, 36(1): 109-115.

DOI: 10.1109/apemc.2010.5475850

Google Scholar

[2] Peng Yu-Jun. The interference of corona from power line. China Science and Technology Information. 2005(21): 127.

Google Scholar

[3] Gary Eng. C., Dr. Dragan Ing. G., Dr. Lungu I. Impulse corona discharge energy around the conductor[C]. [S.L. ]: [s. n. ]: 1990, 1: 922-924.

Google Scholar

[4] Zebboudj Y. Measurements of current and electric field distributions beneath a positive DC wire-to-plane corona using a liner biased probe[C]. [S.L. ]: [s. n. ]: 2000, 147(2): 74-80.

DOI: 10.1049/ip-smt:20000082

Google Scholar

[5] Zhang Hai-Feng, Pang Qi-Chang, Chen Xiu-Chun. The Characteristics of High—Voltage Corona and Its Detection[J]. Electrical Measurement & Instrumentation. 2006, 43(2): 6-8.

Google Scholar

[6] Liu Shang-He, Wei Ghuang-Hui, Liu Zhi-Cheng. Theories and Protection of Electrostatic. Beijing: Publishing House of Weapon Industry, 1999: 181-182.

Google Scholar

[7] Zhu Chang-Qing, Liu Shang-He, Wei Ming. An Analysis and Calculation on Spectrum of ESD Current. High-voltage Engineering. 2003, 29(08): 23-25.

Google Scholar

[8] Guo Shuo-Hong. Electrodynamics. Beijing: Higher Education Press, 2008: 110-121.

Google Scholar