Aquatic Products Determination of Nonylphenol and Octylphenol

Article Preview

Abstract:

By solid - phase extraction high performance liquid chromatography determination of nonylphenol, Octylphenol in aquatic product residues, to establish more accurate, fast, effective detection method. Sample is 3 trichloroacetic acid solution after extraction, using anion exchange solid phase extraction column purification by reversed phase high performance liquid chromatography method for determination. Column is Shim-pack VP-ODS 250mm x4.6mm, detection wavelength is225 nm, mobile phase of methanol - water ( volume ratio of 75:25), flow rate is 0.8 mL/min, injection volume is 20 ìL. Octylphenol, nonylphenol respectively in 0.14¡«97.63 ìg/mL ( R=0.9995),0.02¡«51.04 ì g/mL ( R=0.9997) concentration and peak area show a good linear relationship, octylphenol nonylphenol and the recovery is 87.9%¡«93.8%, relative standard deviation is 1.4%¡«3.8%. Solid - phase extraction high performance liquid chromatography method for determination of aquatic product of octylphenol and nonylphenol residue is accurate, rapid, high sensitivity, suitable for aquatic products of octylphenol nonylphenol and detection.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

388-391

Citation:

Online since:

July 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Alexandros G. A, Nikolaos S. T, Michael A. K. 2012. Recent trends in biomonitoring of bisphenol A, 4-t-octylphenol, and 4-nonylphenol [J]. Toxicology Letters, 210(2): 141-154.

DOI: 10.1016/j.toxlet.2011.07.032

Google Scholar

[2] M.J. Lopez-Espinosa, C. Freire, J.P. Arrebola, et al. 2009. Nonylphenol and octylphenol in adipose tissue of women in Southern Spain[J]. Chemosphere, 76(6): 847-852.

DOI: 10.1016/j.chemosphere.2009.03.063

Google Scholar

[3] K.A. Langdon, M. St.J. Warne, R.J. Smernik, et al. 2011. Degradation of 4-nonylphenol, 4-t-octylphenol, bisphenol A and triclosan following biosolids addition to soil under laboratory conditions[J]. Chemosphere, 84(11): 1556-1562.

DOI: 10.1016/j.chemosphere.2011.05.053

Google Scholar

[4] K.A. Langdon, M. St.J. Warne, R.J. Smernik, et al. 2012. Field dissipation of 4-nonylphenol, 4-t-octylphenol, triclosan and bisphenol A following land application of biosolids[J]. Chemosphere, 86(10): 1050-1058.

DOI: 10.1016/j.chemosphere.2011.11.057

Google Scholar

[5] R. Loos, J. Wollgast, J. Castro-Jiménez, et al. 2008. Laboratory intercomparison study for the analysis of nonylphenol and octylphenol in river water[J]. TrAC Trends in Analytical Chemistry, 27(1): 89-95.

DOI: 10.1016/j.trac.2007.10.011

Google Scholar