Laser Array and Key Principles for Smoke Imaging Test

Article Preview

Abstract:

The scene of single laser beam light is too small for the smoke field testing and the synchronization problem also unavoidable when it works at scanning way. In order to insure the measurement precision for the disturbance effect of smoke to imaging detectors, it introduces the design and key principles of lasers array with multi small power same semiconductor laser after beam homogeneous enlarge shaping. It can measure 3.5m×3.5m smoke area which can full of scene of CCD (10o×10o) at 20m distance in the field testing smoke with 3×3 beam homogenous enlarge shaping laser array.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

422-426

Citation:

Online since:

July 2013

Authors:

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] X Yang, Y Yu, Q Zhang et al. (2007) A novel temperature-insensitive strain sensor based on tapered fiber grating. Optoelectronics Letters. 3(5): 0342-0345.

DOI: 10.1007/s11801-007-6191-3

Google Scholar

[2] L Tao, J GAO. (2004) Theory and testing technique of smoke. Beijing: Defense Press 117-121.

Google Scholar

[3] T Shen, She S. (2007) Study on multi-channel measurement of transmissivity of smoke. Electronics Optics&Control. 5: 124-126.

Google Scholar

[4] Y Lin, J Hu, (2008) Laser beam shaping techniques, 6: 1-4.

Google Scholar

[5] Y Li, W Wang, (2011) Beam Shaping and Homogenization System with Lens Array for Ophthalmic Excimer Laser Refractive Surgery. Optics journal. 081403: 1-4.

Google Scholar

[6] G Du, T Chen, (2005) Lens Array Homogenizer f or Excimer Lasers. Journal of Optoelectronics ·Laser, 3: 279-281.

Google Scholar

[7] H Yi, Y Su, (2011) Modeling and experimental validating on array combination of rectangle laser beams. Infrared and Laser Engineering, 3: 472-475.

Google Scholar

[8] P Yang, G Feng, (2011) Mid-infrared High Energy Laser Beam Detector Array. Chinese Journal Of Lasers, 7: 070200821-070200826.

Google Scholar

[9] H Li, (2005) Research for the efficacy of laser to IR imaging guiding system Changsha: Defense science and Technique University master degree thesis, 4(2)40-47.

Google Scholar

[10] S Jiang, X Hua (2011) Vertical coordinates measurement based on laser screen and photodiode arrays. Journal of Ballistics, 3: 89-92.

Google Scholar

[11] Q Chen, W. Xu (2007) Test of beam homogeneity of plane-array laser's output light pane. Jouranl of Dalian maritime university, 33: 44-46.

Google Scholar