Study on Velocity Variation of Primary Air in Power Plants

Article Preview

Abstract:

Uniform velocity of primary air is very important in the operation of utility boilers. Regulation of the resistance of each pipe was done without pulverized coal to achieve equal flow velocity. The mass flow rate of pulverized coal and the length difference of pipes would lead to velocity variation of primary air. By the research of primary air flow and the regulation process, model of the velocity variation was built to calculate the velocity of each pipe and their difference. The arrangement of pipes and the operation parameters were taken into consideration. With the experimental data, calculation of velocity under different states was made. The velocity difference of different pipes was estimated. The length difference between pipes and the variation of the mass flow rate of pulverized coal play the most important role that affects the velocity of primary air.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

1342-1345

Citation:

Online since:

July 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Pan Weiguo, Cao Jiangmin: Study on Dynamic Method of Primay Air Piping Resistance of Utulity Boilers. China Electricpower. 1999; Vol. 32(1999), pp.28-30.

Google Scholar

[2] Xingsen Yang, Jing Yin: Research on Equal Flow Distribution of Pulverized Coal-Air Mixture in Parallel Pipeline. Applied Mechanics and Materials. 2013; Vol. 252(2013), pp.259-262.

DOI: 10.4028/www.scientific.net/amm.252.259

Google Scholar

[3] Yu Rongxian, Wang Wenqi: Engineering Fluid Dynamics (South East University Press, 1994).

Google Scholar

[4] Huang Biao: Pneumatic conveying (Shanghai Science and Technology Press, 1984).

Google Scholar

[5] Wang Wenqi: Two Phase Flow (Hydro & Electric Power Press, Beijing 1989).

Google Scholar