Pipeline Support under the Loads of Comparative Analysis
Abstract:
This article mainly analyzed the load of fixed and movable pipe supports in the catalyst factory,then classified the load. A calculation was made using MIDAS/CIVIL software modeling. The results show that the bending moment and displacement are all the same in axial of movable and fixed pipe supports, and the axial displacement is influenced heavily by load. Fixed pipe supports are less affected by lateral load, but movable pipe supports are more affected by lateral load. The results can help us to design the pipe supports reasonably.
Info:
Periodical:
Pages:
1641-1647
Citation:
Online since:
August 2013