Shear Strength of Connections between Concrete Filled Steel Tubes and Beams

Article Preview

Abstract:

Departure from the stress state of the steel pipe concrete dye column node, axial force, steel pipe column end moments and stained end vertical shear strength Shear strength concrete filled steel tube the formula, using the finite element analysis software ANSYS to establish a three-dimensional nonlinear finite element model, comparing the results calculated by the finite element calculations and formulas seen, the model is applied to the concrete filled steel tube - steel beam finite element nodes analysis.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

75-79

Citation:

Online since:

August 2013

Authors:

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] ZHONG Shan-tong. Steel pipe concrete structure [M], Harbin: Heilongjiang Science and Technology Publishing House, 1994. In Chinese.

Google Scholar

[2] TANG Jiu-ru. Reinforced concrete frame joints earthquake [M] 1 Nanjing: Southeast University Press, 1989. In Chinese.

Google Scholar

[3] Zhang Da-xu, ZHANG Su-mei. Steel tubular column and beam joints shear capacity [J] 1 Harbin Architectural University, 2001, 34 (1): 21 ~ 27. In Chinese.

Google Scholar

[4] Liu Zhe. Under low cyclic loading outsourcing steel joints' shear performance of research [D] Harbin: Harbin Institute of Civil Engineering and Architecture, 1990. In Chinese.

Google Scholar

[5] ZHANG Da-xu. Theoretical and experimental study of the dynamic performance of concrete filled steel tubular beam-column joints [D] Harbin: Harbin Construction Engineering University, 2000. In Chinese.

Google Scholar