Analysis on Bearing Capacity of Double Back-to-Back Cold-Formed Thin-Walled C Steel Composite Column with Gusset Plate

Article Preview

Abstract:

According to the composite column of double back to back cold-formed thin-walled C steel connected with gusset plate, the experiment and finite element analysis were carried out to study the stability bearing capacity and failure modes of columns under eccentric loading. The factors such as slenderness ratio, eccentricity, gusset plate thickness and spacing were discussed, which produced the impacts to bearing capacity, and the relationship between stiffness and axial load. The results revealed that the failure modes belonged to the in-plane-flexural buckling and local-buckling of the pressurized flanges and webs of the columns. Slenderness ratio, eccentricity and gusset plate spacing are the major factors that affected the mechanical behavior, while the gusset plate thickness has no obvious impact. In the end, compared with the calculation of the bearing capacity of the cold-formed thin-walled column and GB50018-2002, some suggestions based on this composite column calculation were put forward, and the correction coefficient of bearing capacity of the composite columns were given.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

821-824

Citation:

Online since:

August 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] JOHN T. DEWOLF T. Local and Overall Buckling of Cold-formed Steel Members [J]. Journal of the Structural Division, ASCE, 1974, Oct, 2017-(2036).

DOI: 10.1061/jsdeag.0003909

Google Scholar

[2] The standard of the people's Republic of China, Technical specification for cold-formed thin-walled steel structure GB50018-2002 [S]. China Planning Press, (2002).

Google Scholar

[3] SCHAFER B W. Local Distortional, and Euler Buckling of Thin-Walled Columns [J]. Journal of the Structural Engineering, ASCE, 2002, 128(3): 289-299.

DOI: 10.1061/(asce)0733-9445(2002)128:3(289)

Google Scholar

[4] Luo Hong-guang, Guo Yao-jie, Li Kun etc. Cold-formed Lipped Channels axial compression column buckling utility computing research[J], industrial architecture, 2011, 41(8): 96-100. (in chinese).

Google Scholar

[5] Zhao Gentian, Sun Yang, Chen Ming. Experimental study of the mechanical properties of cold-formed thin-walled C Steel Stub Columns[J]. Journal of Inner Mongolia University of Science and Technology, 2011, 9(26): 258-262. (in chinese).

Google Scholar