Research for Start-Up Experiment about IC Reactor to Treat Straw-Washing Wastewater in Straw Based Pulping and Papermaking
Abstract:
In this paper, an IC reactor whose effective volume was 6m3 was used in the experiment to determine the best condition when decontaminating the straw-washing water produced in the straw-based pulping and papermaking industry. The best condition of IC reactor to treat straw-washing wastewater through experiment was: the pH should be controlled in the neutral range, not less than 6.6; the temperature should be maintained at about 31°C, not more than 35°C; the fluctuation range of volume loading should better not be over 15%; To meet the alkalinity of the reactor over 1000mg/L, the dosage of sodium bicarbonate was 12kg / d. In the processing of reactor treating straw-washing wastewater, COD removal rate was lower, and effluent VFA stayed at a high level continuously. So the hydrolysis-acidification process was more appropriate than anaerobic treatment when decontaminating the straw-washing water.