Limited Analysis the Operation Parameters of Float Glass Melting Tank and Flue Gas Desulfurization Correlation

Article Preview

Abstract:

The float glass melting tank is huge and complex equipment which the operation parameters are difficult to control in production line. The install of desulfurizer makes the kiln more complex and unstable. In present work, we fulfill the field experiments and obtained the optimal practical operation parameters. The obtained parameters were: aperture of wings gate: 75-85%; aperture of draft fan: 30-35% for draft fan 1, and draft fan 2 were through-type; aperture of conveying fan: 70-85%; temperature of gas into desulfurizer: 180-200°C; the water flow were controlled by thermocouple and diaphragm control valve; Velocity of gas into desulfurizer: 8-10 m/s. Our results provide the guidance for installing the desulfurizer and modifying the whole system in practice.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

845-849

Citation:

Online since:

August 2013

Authors:

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] N Xu, Q H Zhang, H Wang, Y X Liu, Numerical Stimulation of the Parameters Affect Desulfurization Efficiency in the Flue Gas Desulphurization System [J], J. Wuhan. Univ. Technol., 2011, 33: 109-113.

Google Scholar

[2] J N Wang, J T Yang, S B Grumet, J Schreifels, SO2 Emissions Trading Program: a Feasibility Study for China [M], China Environmental Science Press, Beijing, China, (2002).

Google Scholar

[3] Y Zhao, M B McElroy, J Xing, L Duan, C P Nielsen, Y Lei, J Hao, Multiple effects and uncertainties of emission control policies in China: Implications for public health, soil acidification, and global temperature [J], Sci. Total. Environ., 2011, 409(24): 5177-87.

DOI: 10.1016/j.scitotenv.2011.08.026

Google Scholar

[4] W P Du, Y S Wang, T Song, J Y Xin, Y S Cheng, D S Ji, Characteristics of atmospheric pollutants during the period of summer and autumn in Shijiazhuang [J], Huang Jing Ke Xue, 2010, 31: 1409-1416.

Google Scholar

[5] S Wang, L Zhang, Y Wu, M P Ancora, Y Zhao, J Hao, Synergistic mercury removal by conventional pollutant control strategies for coal-fired power plants in China, J. Air. Waste. Manag. Assoc., 2010, 60(6): 722-730.

DOI: 10.3155/1047-3289.60.6.722

Google Scholar

[6] Y Zhao, L Duan, J Xing, T Larssen, C P Nielsen, J Hao, Soil acidification in China: is controlling SO2 emissions enough, Environ. Sci. Technol., 2009, 43(21): 8021-8026.

DOI: 10.1021/es901430n

Google Scholar

[7] N Xu, Research on the Key Technologies of Float Glass Tank Flue Gas Desulfrization System [D], " Doctor, s Degree of Wuhan University of Technology. 2007, Wuhan.

Google Scholar