Effects of Aspect Ratios on Average Daily Solar Energy Collection for Different Flat-Plate Collector Arrays in Winter Months

Article Preview

Abstract:

A solar radiation model to determine solar energy collection on solar collector array with different aspect ratios has been developed. The relations between the aspect ratio and the average daily solar radiation collection on the collector array have been deeply studied. The results show that there is an optimum aspect ratio to maximize the solar energy collection on the collector arrays. The optimum aspect ratios of the 1000 m2 collector array for Haikou, Kunming, Lhasa and Beijing are 10/1, 1/3, 5/1 and 10/1.The optimum aspect ratios of 1000 m2, 500 m2, 200 m2 and 100 m2 collector arrays for Kunming are 1/3, 3/1, 7/1 and 1/5, respectively.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

1228-1231

Citation:

Online since:

August 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] J. Appelbaum and J. Bany. Shadow effect of adjacent solar collectors in large scale systems. Solar Energy, 1979, 23(6): 497-507.

DOI: 10.1016/0038-092x(79)90073-2

Google Scholar

[2] R.E. Jones JR., J.F. Burkhart. Shading effect of collector rows tilted toward the equator. Solar Energy, 1981, 26(6)563-565.

DOI: 10.1016/0038-092x(81)90171-7

Google Scholar

[3] H. Zhai, Y.J. Dai, J.Y. Wu, et al. Research on arrangement problem of large scale flat plane/evacuated tube solar collector array. Acta Energiae Solaris Sinica, 2008, 29(5): 564-568. (in Chinese with English abstract).

Google Scholar

[4] GB 50364-2005. Technical code for solar water heating system of civil building. The industry standard of the People's Republic of China, (2005).

Google Scholar

[5] R.S. Tang, T. Wu. Optimal tilt-angles for solar collectors used in China. Applied Energy, 2004, 79(3): 239–248.

DOI: 10.1016/j.apenergy.2004.01.003

Google Scholar

[6] G. Notton, C. Cristofari, P. Poggi. Performance evaluation of various hourly slope irradiation models using Mediterranean experimental data of Ajaccio. Energy Conversion and Management, 2006, 47 (2): 147-173.

DOI: 10.1016/j.enconman.2005.03.022

Google Scholar

[7] G. Huseyin, H. Arif. Determination of the optimum tilt angle of solar collectors for building applications. Building and Environment, 2007, 42 (2): 779-783.

DOI: 10.1016/j.buildenv.2005.09.012

Google Scholar

[8] S.X. Wei, Z.Y. Zhang, X.F. Zhou, et al. Effects of aspect ratio on average daily shading factor of flat-plate solar collector array in winter months. Applied Mechanics and Materials, 2012, Vols. 193-194, pp.227-230.

DOI: 10.4028/www.scientific.net/amm.193-194.227

Google Scholar