Research of Quantitative Analyzer for Fluorescence Immune Chromatography Strips

Article Preview

Abstract:

Fluorescence immunoassay technology is widely recognized as the most sensitive detection technology, now widely used in clinical testing. The research of quantitative analyzer for fluorescence immune chromatography strips is of great significance. In this thesis, a quantitative analyzer for fluorescence immune chromatography strips has realized, based on photoelectric detection principle and immunochromatographic. The system uses LPC1788 and MSP430 as processors. Using some algorithms such as low-pass filtering, least square method and area method to analyze the detected waveform and eliminate noise with high accuracy. In our experiment, the minimum detection concentration is at several mIU/ml levels, the relative standard deviation is less than 2% and it has good linear response characteristics in a concentration range from 0.5125 to 952mIU/ml while the correlation coefficient R2 is 0.981. The instrument has a good prospect.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

1000-1006

Citation:

Online since:

August 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Kang Chen. Structure, Principle and Progress of Fluorescence Immunity Analyzer. China Medical Equipment, 2009, 24(2): 1-3.

Google Scholar

[2] Dong Seok, Eui Yul Choi. Simultaneous Quantitative Determination of Multiple Analytes with Fluorescence-Tagged Probes by Immunochromatography. Korean Journal of Biological Sciences, 2003, 7(1): 10-20.

DOI: 10.1080/12265071.2003.9647688

Google Scholar

[3] Bingqiang Ren, Lihua Huang, Huijie Huang. Time-resolved fluorometer based on immunochromatography. Chinese Journal Of scientific Instrument, 2009, 30(6): 1-4.

Google Scholar

[4] Yang Wang, Kai Jiang, Ping Wang, Jiyu Han. Development of quantitative analytical instrument for colloidal gold strips based on light source modulation technique. Electric technology application, 2012, 38(12): 1-5.

Google Scholar

[5] Juntao Liu, Zonghui Guo, Cunxiu Liu. Research of Optic Quantitative Test System Combined withImmunochromatographic Strip. Micronanoelectronic Technology, 2007, 44(7): 1-4.

Google Scholar

[6] K Pettersson, H Siitari, I Hemmila. Time-resolved fluoroimmunoassay of human choriogonadotropin. Clinical Chemistry, 1983, 29(1): 60-64.

DOI: 10.1093/clinchem/29.1.60

Google Scholar

[7] Tian Zhen, Yanbin Zhu, Zhouyi Guo. Design and Performance of A Sensitive Time-resolved Fluorometer. Optoelectronics·Laser, 2006, 17(9): 1-6.

Google Scholar

[8] Lei Liu, Lei Zhou, Lihua Huang. CCD-based detection system for immunity-chromatography test strip. Scientific Instrument, 2007, 28(2): 2-4.

Google Scholar