The Stress Analysis of Joint Connecting Bolt of Submersible Electric Pump

Article Preview

Abstract:

Submersible electric pump units are connected by bolts. This paper uses finite element analysis method to simulate how the pump joint bolt behave when it transmit torque.In this paper, temperature method is adopted to simulate the bolt preload and axial deformation.It also used to analyse and calculate the limited value when submersible electric pump units transmit torque under different preload. All of this provide the designing of connecting bolt preload and construction with theoretical basis.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

246-249

Citation:

Online since:

August 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Finite Element Analysis Software-ANSYS digest. China WaterPower Press. 2002: 230-247.

Google Scholar

[2] Liu Jubao. Finite Element Analysis of Oil Equipment[M]. Beijing: Petroleum Industry Press, 1996, 205-212.

Google Scholar

[3] Chu Tai'an Bolt Tightening Method and the Preload Force Control[J]. Process Equipment & Piping, 2005. 3(42): 8-10.

Google Scholar