Damage Evaluation of Concrete Based on Acoustic Emission b-Value

Article Preview

Abstract:

Acoustic emission (AE) is capable of real time continuous monitoring and it's not sensitive to the geometry of components,so it's widely used in nondestructive testing of concrete. The AE b-value occupies an important position in the study of concrete damage evaluation as a parameter of AE technology. The basic theory of AE b-value and the related technical problems of AE b-value calculation was discussed. Then the research of AE b-value on concrete was reviewed. At last, the AE b-value in the damage process of cement mortar (CM) and polypropylene diber reinforced mortar (PFRM) under compression was studied and concluded that the trend of AE b-value of CM and PFRM was obviously different.The AE b-value is closely related to the formation and propagation of cracks in the damage process of concrete and it declines rapidly before final fracture occurs.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

515-519

Citation:

Online since:

September 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[2] Dimitrios G. Aggelis, Tomoki Shiotani, Shouhei Momoki, et al. Acoustic Emission and Ultrasound for Damage Characterization of Concrete Elements[J]. Materials Journal, 2009, 106(6): 509-514.

Google Scholar

[3] M. Ohtsu. The history and development of acoustic emission in concrete engineering[J]. Mag. Concr. Res, 1996, 177(48): 321-330.

Google Scholar

[4] D.G. Aggelis, D.V. Soulioti, N. Sapouridis, et al. Acoustic Emission Characterization of The Fracture Process in Fibre Reinforced Concrete[J]. Construction and Building Materials, 2011, 25(7): 4126-4131.

DOI: 10.1016/j.conbuildmat.2011.04.049

Google Scholar

[5] Gutenberg, B., Richter, C. F. In Seismicity of the Earth and Associated Phenomena[J]. Princeton University Press, Princeton, NJ, USA, 1954, 2nd edn.

Google Scholar

[6] R. Vidya Sagar, B.K. Raghu Prasad, S. Shantha Kumar. An experimental study on cracking evolution in concrete and cement mortar by the b-value analysis of acoustic emission technique[J]. Cement and Concrete Research, 2012, 42(3): 1094-1104.

DOI: 10.1016/j.cemconres.2012.05.003

Google Scholar

[7] Shiotani, T., Fujii, K., Aoki, et al. Evaluation of progressive failure using AE sources and improved b-value on slope model tests[J]. Prog. Acoust. Emission, 1994, VII, 529-534.

Google Scholar

[8] Shiotani, T., Yuyama, S., Li, Z. W., et al. Application of AE improved b-value to quantitative evaluation of fracture process in concrete materials[J]. Journal of Acoustic Emission, 2001, 19, 118-133.

Google Scholar

[9] S Colombo, IG Main, MC Forde. Assessing Damage of Reinforced Concrete Beam Using b-value Analysis of Acoustic Emission Signals[J]. Journal of Materials in Civil Engineering, 2003, 15(3): 208-286.

DOI: 10.1061/(asce)0899-1561(2003)15:3(280)

Google Scholar

[10] Alireza Farhidzadeh, Ehsan Dehghan-Niri, Salvatore Salamone, et al. Monitoring Crack Propagation in Reinforced Concrete Shear Walls by Acoustic Emission[J]. Journal of Structural Engineering, in press: (doi: 10. 1061/(ASCE)ST. 1943-541X. 0000781).

DOI: 10.1061/(asce)st.1943-541x.0000781

Google Scholar

[11] Kurz JH, Finck F, Grosse CU, et al. Stress drop and stress redistribution in concrete quantified over time by the b-value analysis[J]. Struct Health Monit, 2005, 5: 69-81.

DOI: 10.1177/1475921706057983

Google Scholar

[12] A. Carpinteri, G. Lacidogna, G. Niccolini. Fractal Analysis of Damage Detected in Concrete Structural Elements under Loading[J]. Chaos, Solitons and Fractals, 2009, 42(3): 2047-(2056).

DOI: 10.1016/j.chaos.2009.03.165

Google Scholar

[13] Alberto Carpinteri, Giuseppe Lacidogna, Simone Puzzi. From Criticality to Final Collapse: Evolution of The b value from 1. 5 to 1. 0[J]. Chaos, Solitons and Fractals, 2009, 41(4): 843-853.

DOI: 10.1016/j.chaos.2008.04.010

Google Scholar

[14] Yuma Kawasaki, Yuichi Tomoda, Masayasu Ohtsu. AE Monitoring of Corrosion Process in Cyclic Wet–dry Test[J]. Construction and Building Materials, 2010, 24(6): 2353-2357.

DOI: 10.1016/j.conbuildmat.2010.05.006

Google Scholar

[15] Santosh G. Shah, J.M. Chandra Kishen. Use of Acoustic Emissions in Flexural Fatigue Crack Growth Studies on Concrete[J]. Engineering Fracture Mechanics, 2012, 87(6): 36-47.

DOI: 10.1016/j.engfracmech.2012.03.001

Google Scholar

[16] Amadeo Benavent, Enrique Castro, Antolino Gallego. Evaluation of Low-cycle Fatigue Damage in RC Exterior Beam-column Subassemblages by Acoustic Emission[J]. Construction and Building Materials, 2010, 24(10): 1830-1842.

DOI: 10.1016/j.conbuildmat.2010.04.021

Google Scholar

[17] A. Carpinteri, G. Lacidogna, A. Manuello. The b-Value Analysis for the Stability Investigation of the Ancient Athena Temple in Syracuse[J]. Strain, 2011, 47(s1): 243-253.

DOI: 10.1111/j.1475-1305.2008.00602.x

Google Scholar