Developing and Research on Liquid Level Control System of Double-Tank

Article Preview

Abstract:

In the paper, the liquid level control system of double-tank is built, which bases on MCGS configuration software. Taking the liquid levels of double-tank as control object, the mathematics model is built, which is used for experiment and research. Moreover, the liquid level PID adjustor of single tank is designed, and P, PI and PID experiments are done in the step signal, which has important practical significance and reference value.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

1200-1203

Citation:

Online since:

September 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Lihui Feng. Microcomputer recast of tank liquid level analog control system[J]. Kunming science and technology university journal. 2001, 24(5): 1-4.

Google Scholar

[2] Yi Wang, Zaoxiao Zhang. Process equipment control technology and application[M]. Chemistry Industry Press, (2007).

Google Scholar

[3] Noura Hassan, Theilliol Didier, Sauter Dominique. Actuator Fault-Tolerant Control Design: Demonstration on A Three-Tank System. International Journal of Systems Science, September 2000: 1143~1155.

DOI: 10.1080/002077200418414

Google Scholar

[4] Uchida M., Nakano K. Simulator-Based Foresight Control of Level of Three tanks in Series, Industrial Electronics, Control, and Instrumentation, 1996., Proceedings of the 1996 IEEE IECON 22nd International Conference on, Volume:1, 5-10 Aug. 1996:321~325.

DOI: 10.1109/iecon.1996.570972

Google Scholar