Research on the New Type of 12kV Inflatable Vacuum Circuit Breaker

Article Preview

Abstract:

With the rapid development of domestic economy and the construction, the application of 10 kV power system is more and more extensive and the environment of the application is also more and more complicated. Aiming at this situation, in this paper, a new-type circuit breaker is proposed for the outer environment, which is based on the Water pressure up case configuration. The configuration is fully-enclosed, small size, light-weight, and it is applicable to high temperature and humid areas. In order to study characteristics of the permanent magnetic force (PMA), the paper adopts the electromagnetic analysis software ANSOFT to analyze its static and dynamic characteristics. The experiment results show that the performance of PMA is reliable. In order to analyze the insulting property of its enclosure design with new-style and small size, ANSOFT electric field is adopted to conduct simulation analysis and the experiment results show that the design and improvement measure are stable and reliable.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

1230-1235

Citation:

Online since:

September 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Yihan Yang, Power system infrastructure: China Electric Power Press (2006) In Chinese.

Google Scholar

[2] Li Rui, Li Jianji, Tan Yan, et al. the safe use of SF6 in high voltage switchgear: Electrical application-Metallurgy Electrical, Vol. 28 (2009), pp.16-20.

Google Scholar

[3] Li Jianji, Non-filling SF6 gas filled cabinet (C-GIS): Electrical Technology, Vol. 4 (2006), pp.64-67.

Google Scholar

[4] Guo Shizhao, Comparison on the reliability of electrical and mechanical linkage of high voltage circuit breaker: Electrical Switch, No. 6 (2003), pp.23-26.

Google Scholar

[5] Zheng Xianbin, Electrical and mechanical linkage of circuit breaker in GIS: Electrical Manufacturers, No. 4 (2011), p.37.

Google Scholar

[6] Jong-Ho Kang, Chae-Yoon Bae, and Hyun-kyo Jung, Dynamic behavior analysis of permanent magnetic actuator in vacuum circuit breaker: The Sixth International Conference on Electrical Machines and Systems (2003) pp.100-103.

Google Scholar

[7] Liu Fugui, Guo Hongyong, Yang Qingxin, et al. An improved approach to calculate the dynamic characteristics of permanent magnetic actuator of vacuum circuit breaker: IEEE Transactions on Applied Superconductivity (2004) p.1918-(1921).

DOI: 10.1109/tasc.2004.830931

Google Scholar

[8] Zou J Y, Duan X Y, Dong E Y, Permanent magnetic actuator and electronic drive for vacuum switches: Proc. 5th Inter. Conf. on Elec. Machines and Systems (2001) pp.1323-1326.

Google Scholar