The Principle and Calibration of the Third Gear Flow-Meter

Article Preview

Abstract:

At present, the domestic development of the gear flow-meter is far behind the developed countries, especially in the micro gear flow-meter. This paper proposes a typical structure named the third gear flow-meter. The structural characteristics and working principle of the third gear flow-meter was introduced in detail, the prototype of the third gear flow-meter was designed and processed, and the calibration tests and pressure experiments of the third gear flow-meter prototype was made at last. We can draw that the three gear flow-meter can be used in hydraulic system pressure range is less than 25Mpa, the flow rate was 0.15~0.2m3/h can meet the high requirements of the stability of measurement, and the measurement accuracy in the whole flow range is 0.2 class. This article provides a reliable experimental data for the design of the micro gear flow-meter.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

1713-1717

Citation:

Online since:

September 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Chen Yijian . High two meters high bi-directional elliptical gear flow-meter study [Dissertation]. Zhejiang University. 2008 (In Chinese).

Google Scholar

[2] Liu Lianzhu . Who flow calibration measurement system device research [Dissertation]. Northeastern University. 2008 (In Chinese).

Google Scholar

[3] Pan Wei. Research on turbine flow-meter calibration based on control system. [Dissertation] Dalian. 2006 (In Chinese).

Google Scholar