Shaking Table Test of RC Frame-Shear Wall Structures with Partial Columns Sliding at Upper Ends

Article Preview

Abstract:

A new kind of RC frame-shear wall structures with partial columns sliding at upper ends is proposed in this paper. A shaking table test of this new kind of structure model (Model B) and a conventional frame shear-wall structure Model (Model A) were carried out, and the plan layout and the member size of the two models are nearly identical. The two models are 3-story and 2-bay by 2-bay, and the second story of either structure is weak story. The test results showed that: (1) under the same intense earthquake, the damage of Model B is slighter than that of Model A; and (2) under the same intense earthquake, the interstory drift angle, the acceleration and the shear force of weak story of Model B are reduced remarkably in comparison to Model A.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

795-798

Citation:

Online since:

September 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] GB50011-2010: Code for seismic design of buildings. (China Arch. and Bldg Press, China, 2001).

Google Scholar

[2] Wu Bo, Lu Wenlong, Xiong Wei: Engineering Mechanics, Vol. 28 (2011): p.82. (in Chinese).

Google Scholar

[3] Wu Bo, Lu Wenlong: Engineering Mechanics, Vol. 29 (2012): p.143. (in Chinese).

Google Scholar

[4] Mokha A, Constantinou M, Reinhorn A: J. of Structural Engineering, Vol. 116(1990): p.438.

Google Scholar