Finite Element Analysis on Integral Structure of Light Steel Temporary Buildings

Article Preview

Abstract:

Light steel temporary building is commonly used in the construction site, with advantages on simple structure, repeat used and small deadweight. There are still not enough researches and relevant standards to conduct the design and construction of the buildings. In order to precede to theoretical study on integral structure of light steel temporary buildings a method which used to set up finite element analysis model about integral structure of light steel temporary buildings was proposed in this paper. The method is based on finite element analysis software, Ansys. Using this method a monolayer integral structure, a two-story integral structure and a trilaminar integral structure model were set up. Lateral displacement under design load of the integral structure was solved out by these finite element models.