Study on Earthquake Resistant Performance of a Large Span Structure Strengthened with HADAS

Article Preview

Abstract:

Seismic fortification intensity has been adjusted in some areas which were affected in The Wenchuan-earthquake. It was seismic strengthening for most of the buildings especially the public buildings after the adjustment. In order to ensure the seismic performance of the structure after reinforcement ,the analysis method based on performance is gradually applied in the large and complex engineering structure analysis .The paper uses a large span Sports Training Center under construction as background. According to the situation that the fortification intensity by 6 degrees improved to 7 degrees ,the paper uses Push-over method to analysis elastic-plastic of the finite element models ,which including the mild steel damper before and after reinforcement ,under the action of the rare earthquake of 7 degrees. The paper is studying the internal force,deformation and destruction of the structure in the action of the rare earthquake,comparing the dynamic characteristics and seismic performance of the models, and researching distribution of weak links and plastic hinge of the models under the large earthquake. The results show that the models can meet collapse resistant checks less than 7 degrees of the rare earthquake before and after reinforcement. The second floor is relatively weak of the original structure,and can emerge local damage easily. But the structures stiffness is more uniformly after reinforcement, and has large resistance of the collapsed ability.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

933-939

Citation:

Online since:

September 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Zhou Y. Reinforcement Design for Earthquake. Resistant of Energy Dissipation Structure [M]. Beijing science Press, 2006. (In Chinese).

Google Scholar

[2] GB 50011-2001; Code in seismic design of buildings[S]. Beijing: China Building Industry Press, 2002. (In Chinese).

Google Scholar

[3] ANIL K C, RAKESH K G. A modal pushover analysis procedure to estimate seismic demands for buildings: Theory and Preliminary Evaluation[R]. PEER Report 2001(03), Pacific Earthquake Engineering Research Center, College of Engineering University of California Berkeley, (2001).

Google Scholar

[4] Skinnner R I, Kelly I M, Heine A J, Robinson W H. Hysteresis dampers for the protection for the protection of structures from Earthquake. Bull N. Z, Nat Soc for Earthquake Engineering, 1980, 13(1): 22-26.

Google Scholar

[5] Tyler R G. Tapered Steel Energy Dissipaters for Earthquake Resistant Structures. Bulletin of New Zealand National Society for Earthquake Engineering, 1978, 11(4): 282-294.

DOI: 10.5459/bnzsee.11.4.282-294

Google Scholar

[6] Li Bin. Application Study on Structural Modal Analysis Method for High-Rise Buildings [D]. Master paper of Tongji University. 2006. (In Chinese).

Google Scholar

[7] Ye Liaoyuan, Pan Wen. Structure Pushover analysis principles and an example [J]. Journal of Building Structures. Vol. 21. No. 1. Feb. 2000. 37-42. (In Chinese).

Google Scholar

[8] Wang Dasui, He Junli, Zhang Fengxin. The basic principles and an example of the nonlinear static analysis (on Pushover Analysis) [J]. World Earthquake Engineering. Vol. 20. No. 1. Mar. 2004. 45-53. (In Chinese).

Google Scholar

[9] ATC40. Seismic evaluation and retrofit of concrect Buildings[S]. California seismic safety commission. November. (1996).

Google Scholar

[10] Pretend and commentary for the Seismic Rehabilitation of Buildings[S]. Federal Emergency Management Agency. FEMA 356/November 2000. (In Chinese).

Google Scholar

[11] Beijing Golden civil Software Technologies Ltd. The Sap2000 of Chinese Edition Guide [M]. China Building Industry Press . 2009. (In Chinese).

Google Scholar