Fire Supervisory System Design Based on Embedded System

Article Preview

Abstract:

This paper introduces fire supervisory system design based on embedded system using by ARM9. Embedded technology and field bus technology are used for the system design. The system can realize detecting on-line. Showing uninterruptedly the information for fire monitory point of the building, the working current for electricity lines, the leakage current, as well as environmental temperature parameters e.g., through the LCD panel. Through this system The fire information of the building and the electrical wiring or the change, fault and abnormal condition for fire danger parameters of the equipment can be mastered at any time, and the hidden fire danger can be found in time, eliminating the hidden fire danger through the alarm and terminal linkage device.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

161-165

Citation:

Online since:

September 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Chen Na. Fire monitoring system design for intelligent building. The first edition. Beijing: Tsinghai university press, (2001).

Google Scholar

[2] National Standards. Design specifications for automatic fire alarm system (GBJ50116-98). Beijing: China plans to press, (1999).

Google Scholar

[3] Mountains. Fire alarm monitors system research and development based on field bus. Low pressure electric appliance. 2006 (11).

Google Scholar

[4] BOSCH. CAN-bus standards V2. 0 edition. (ZhouLiGong SCM development limited company in Guangzhou).

Google Scholar

[5] Xie Qiyuan. Sensitivity evaluation of smoke fire detectors. The fire science. 2004 (2).

Google Scholar

[6] SJA1000 Stand-alone CAN controller data sheet, Philips Semiconductors, 2000 (2) : 144 -148.

Google Scholar

[7] R. Peter Bonasso, David Kortenkamp, David P. Miller and Marc Slack: Experiences with an Architecture for Intelligent, Reactive Agents.

Google Scholar

[8] Barbara Hayes-Roth: An architecture for adaptive intelligent systems.

Google Scholar

[9] Fu,K. Purdue University, Lafayette, IN, USA: Learning control systems and intelligent control systems: An intersection of intelligence and automatic control.

Google Scholar

[10] ARM Limited ARM Development Guide 2000-2001. ARM DOT 0095-1/06. 00. (2000).

Google Scholar

[11] ARM Inc.ARM Architecture Reference Manual[M]. UKARM Inc, (2002).

Google Scholar

[12] SAMSUNG Semiconductors S3C2410 Application Processors Developer's Manual[Z]. SAMSUNG Corp. (2002).

Google Scholar

[13] Bukowski,Budnick,Schemel.Estimates of the Operational Reliability of Fire Protection Systems,Fire Protection Engineering, No. 5, (2002).

Google Scholar

[14] Bushby S.T.Integrating Fire Alarm Systems with Other Building Automation and Controls Systems, Fire Protection Engineering, No. 11, (2001).

Google Scholar