Bridge Structure Detection Based on Load Test

Article Preview

Abstract:

By the detection of a three spans continuous beam bridge, the detection loading method and arrangement of measuring points are discussed, the static and dynamic detection results such as the deflection, stress and inherent vibration frequency are comparative analyzed with those of theoretical calculation. Results show that the bridge is safe under actual working condition, which provides the basis for normal operation and maintenance of the bridge.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

891-893

Citation:

Online since:

October 2013

Authors:

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Y. Guo, X. Li, Study of static and dynamic load tests of XiangQinxia Bridge after strengthened, Sichuan building, 4 (2006) 107-108.

Google Scholar

[2] G. Xu, J. Zhang, Bridge structure detection based on the load test, Popular Science and Technology, 2 (2009) 75-78.

Google Scholar

[3] Z. Liu, Bridge Engineering Testing Handbook, China Communications Press, Beijing, (2001).

Google Scholar

[4] Y. Song, Bridge Loading Tests and Structural Evaluation, China Communications, Beijing, (2002).

Google Scholar

[5] JTG D62-2004, Design Code for Highway Reinforced Concrete and Prestressed Concrete Bridge and Culvert, China Communications Press, Beijing, (2004).

Google Scholar

[6] JTG D60-2004, General Specification for Design of Highway Bridges and Culverts, China Communications Press, Beijing, (2004).

Google Scholar