Extreme Transient Flow in Pumping System due to a Tripping Pump Disturbance

Article Preview

Abstract:

Taking a pumping station project with large scale centrifugal pumps as working example, an extreme transient flow in the pumping system caused by tripping pump due to electric supply failure was analyzed, and hydraulic disturbance or impulsion to the rest working running pumps were investigated by using the software of the Deltares WANDA 3.73. The results show that the rest running pumps in the system due to a sudden tripping pump disturbance are heavy disturbed when the tripping pump is suddenly failed from the pumping system. The flow rate and input power for the working pumps are greatly jumped shortly. The strongly transient impulsion to the pumping system is quite significant.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

233-238

Citation:

Online since:

October 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Yuan Zheng , Jian Zhang. Hydraulic transition process unit[M]. Beijing: Beijing University Press. (2008).

Google Scholar

[2] Zhui Jing, Naichang Jiang, Xinghua Wang. Stop Pumping Water Hammer And Protective Measures[M] . China Building Industry Press. (1993).

Google Scholar

[3] Meiqing Liu, Guanglin Liu, Weimin Feng, Xianhua Feng, Zunxiong Wu. Research On Hydraulic Transients And Operating System for Energy Reserve Rapid drop Gate Of Large Scale Pumping Stations[J]. Journal of agricultural machinery. 2000, 31(3): 55~58.

Google Scholar

[4] Jing Gong, Dafan Yan, Dongjie Tan. Optimization Of Lead Protection Control Plan For Accidental Power-cut At Pumping Station[J]. Oil & Gas Storage With Transport. 1998,17(10):18~21.

Google Scholar

[5] Jinsheng Huo, Ph.D., P.E., BCEE, 2011. Surge Protections for a Major Raw Water Pump and Pipeline System. World Environmental and Water Resources Congress 2011: 1641~1651.

DOI: 10.1061/41173(414)171

Google Scholar

[6] Anton BERGANT, Angus R. SIMPSON, Esad SIJAMHODZIC. Water Hammer Analysis of Pumping Systems for Control of Water Underground Mines. International Mine Water Association 2012: 9~20.

Google Scholar

[7] Dakai Liu. Water Turbine [M]. Beijing: China Water Power Press. (1996).

Google Scholar

[8] Streeter, V. L: Water Hammer Analysis, Journal of the Hydraulics Division, Nov. (1969).

Google Scholar

[9] Streeter, V. L: Water Hammer Analysis Including Fluid Friction, Journal of Hydraulics Division, V01. 88. May (1962).

DOI: 10.1061/jyceaj.0000736

Google Scholar

[10] Juan Liang. The Computation Research of the Cutoff and Non-cutoff Suddenly Pump-stopping Hammer in the Single Water Source Urban Water Supply Pipe Network[D]. Xi'an:School Of Environmental Science and Engineering, Chang 'an University, 2011: 19~20.

Google Scholar

[11] Weyler, M. E. and V. L. Streeter: An Investigation of the Effect of Cavitation Bubbles on the Momentum Loss in Transient Pipe Flow, Journal of Basic Engineering, V01. 91, March1971.

DOI: 10.1115/1.3425170

Google Scholar