Design and Simulation Analysis of Pile Foundation Ground Source Heat Exchanger System

Article Preview

Abstract:

Pile foundation thermal response test method was adopted to measure the heat transfer capacity of the pile foundation U-pipe heat exchanger of large buildings in Shanghai. The heat exchanger system of pile foundation buried pipe was designed. CFD numerical simulation method was adopted to analyze temperature distribution characteristics of a single concrete pile and dense arrangement of concrete piles heat exchanger. Further, the number and spacing of ground heat exchanger with U-type pile foundation was optimized design . Finally, the U-shaped heat exchanger was buried in the pile base system which was designed to require 24 piles and pile spacing at 12m.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

2815-2818

Citation:

Online since:

October 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] L. Laloui,M. Moreni,L. Vulliet, Behavior of a dual-purpose pile as foundation and heat exchanger, Canadian Geotechnical Journal, 2003, 40 (2):388-402.

Google Scholar

[2] L. Laloui, M. Nuth, L. Vulliet, Experimental and numerical investigations of the behavior of a heat exchanger pile, International Journal for Numerical and Analytical Methods in Geomechanics, 2006, 30 (8):763-781.

DOI: 10.1002/nag.499

Google Scholar

[3] Yaxin Li, Study on the heat exchange and recovery characteristic of pile foundation ground source heat pump group, Tongji university, master of engineering thesis, Shanghai, 2007. 3.

Google Scholar

[4] Xilong Gong, Zhihua Zhou, Yang Yu, Study on heat transfer performance of buried tube heat exchanger inside foundation pile, Gas and Heating power, 2008. 4, Vol. 28 No. 4: 1-3.

Google Scholar

[5] Jun Zhao, Huajun Wang, Numerical simulation on heat transfer characteristics of soil around compact pile-buried underground heat exchangers, HVAC, 2006, Vol. 36(2): 11-15.

Google Scholar

[6] Jun Gao, Xu Zhang , Jun Liu, Kuishan Li, Jie Yang. Numerical and experimental assessment of thermal performance of vertical energy piles: An application. Applied Energy, 2008, 85(10):901–910.

DOI: 10.1016/j.apenergy.2008.02.010

Google Scholar

[7] Jun Gao, Xu Zhang, Jun Liu, Kui Shan Li and Jie Yang, Thermal performance and ground temperature of vertical pile-foundation heat exchangers: A case study, Applied Thermal Engineering, Volume 28, Issues 17-18, December 2008, Pages 2295-2304.

DOI: 10.1016/j.applthermaleng.2008.01.013

Google Scholar

[8] Xu Zhang, Simulation study on ground-source heat pump performance characteristics in Expo Axis and underground syntheses project, refrigeration technology, 2010supplyment: 13-17.

Google Scholar