Performance Analysis of Photo Voltaic Trombe Wall for Tropical Climate

Article Preview

Abstract:

The present study examines the performance of a single zone building integrated with PV Trombe wall (PV-TW) in term of thermal load reduction and electrical energy production by varying PV Glazing types (i.e. Single Glazing, Double glazing, Double glazing filled with gas (Argon)). TRNSYS software is used for simulation in which inputs like climatic conditions, building construction details, thermal properties of materials, detail of PV-TW and orientation of building is inserted. By comparing the results of all three types of glazing it is found that PV Double glazing filled with argon shows significant reduction in mean air duct temperature, hence reduces the PV cell temperature and increases power production of PV panel. Also solar radiation captured by massive wall of PV-TW is reduced by using PV Double glazing filled with argon as compared to other types of glazing, which further reduces thermal load inside the building.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

211-215

Citation:

Online since:

December 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] European Communities. EU Energy and Transport in Figures 2008. Statistical Pocket Book 2007/2008. Brussels, Belgium, (2008).

Google Scholar

[2] COM. Summary of the Impact Assessment. Communication Staff Working Document, Accompanying Document to the Proposal for a Recast of the Energy Performance of Buildings Directive (2002/91/EC); COM 755/SEC(2008).

Google Scholar

[3] R. Saidur, Energy consumption, energy savings, and emission analysis in Malaysian office buildings. Energy Policy, 37(2009)4104–411.

DOI: 10.1016/j.enpol.2009.04.052

Google Scholar

[4] Directive 2010/31/EU of the European Parliament and of the Council of 19 May 2010 on the energy performance of buildings.

Google Scholar

[5] Y. W. Liu, W. Feng, Integrating passive cooling and solar techniques into the existing building in South China, Advanced Materials Research, 368- 373(2012)3717–20.

DOI: 10.4028/www.scientific.net/amr.368-373.3717

Google Scholar

[6] C. BEGGS, Passive solar and low energy building design, Energy Management and Conservation, (2007)243-270.

DOI: 10.1016/b978-075065096-0/50030-2

Google Scholar

[7] K. B. Kundakci, Z. Yilmaz, The comparison of Trombe wall systems with single glass, double glass and PV panels, Renewable Energy, 45(2012)111–8.

DOI: 10.1016/j.renene.2012.02.026

Google Scholar

[8] J. Jie, H. Yi, W. He, G. Pei, PV-Trombe wall design for buildings in composite climates. Journal of Solar Energy Engineering by ASME, 129(2007)431–437.

DOI: 10.1115/1.2770751

Google Scholar

[9] W. Smolec, A. Thomas, Theoretical and experimental investigations of heat transfer in a Trombe wall, Energy Conversation Management, 4 (5)(1993)385–400.

DOI: 10.1016/0196-8904(93)90089-s

Google Scholar

[10] T. Tsuji, Y. Nagano, Characteristics of a turbulent natural convection boundary layer along a vertical plate, International Journal of Heat Transfer, 31(8) (1988)1723–1734.

DOI: 10.1016/0017-9310(88)90284-0

Google Scholar

[11] H. Yang, J. Burnett, J. Ji, Simple approach to cooling load component calculation through PV walls, Energy and buildings, 31(2000) 285-290.

DOI: 10.1016/s0378-7788(99)00041-9

Google Scholar

[12] T. Y. Chen, A method for the direct generation of comprehensive numerical solar building transfer functions, Solar Energy, 74(2003)123–132.

DOI: 10.1016/s0038-092x(03)00119-1

Google Scholar

[13] W.G.J. Van Helden, R.J.C. van Zolingen, H.A. Zondag, PV thermal systems: PV panels supplying renewable electricity and heat, Progress in Photovoltaics: Research and Applications, 12(2004)415-426.

DOI: 10.1002/pip.559

Google Scholar