A Working of Eddy Current Transducers under Control of Ferromagnetic Pipes in Condition of Insufficient Magnetic Saturation

Article Preview

Abstract:

The numerical method of calculation of electromagnetic field in a control sample at a time of work of encircling eddy current transducer is offered. The method is based on a numerical solution of the two Maxwell equations, which connect a change of electrical and magnetic fields. It allows to make calculations taking into account the actual value of magnetic inductivity of metal and to get results in any form, convenient for further interpretations. For the calculation of the encircling eddy current transducer the equivalent circuit of defect as step junction is offered. The numerical calculation shows, that the greatest sensitivity of the transducer is achieved when the value of magnetic permeability of the object of control is approximately 10-30. Therefore, it is not necessary to lead the material of the object of control up to satiety, as it considered before.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

528-530

Citation:

Online since:

December 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Equations of mathematical physics. А.N. TiHonov, А.А. Samarskiy. -M.: Glavizdat, 1953. -679 p.

Google Scholar

[2] Nondestructive control. Book 3, Electromagnetic control. Edited by V.V. Syhorykov. -.М.: Vishaya shcola, 1992, 490 с.

Google Scholar

[3] Nondestructive control and diagnostics. Reference book. Edited by V.V. Kluev -M.: Mashinostroenie, 1995, 467 с.

Google Scholar