A Study for Removal of Pipe Vibration on Swirlmeter

Article Preview

Abstract:

This paper provides a method to eliminate pipe vibration on swirlmeter. We made an experimental research on a diameter 50 mm swirlmeter to study the influence that pipe vibration on the swirlmeter. Results show that using difference method can eliminate the error caused by pipe vibration by putting two sensors along the same side of the swirlmeters axis and using difference method. The experiment proved the approach using difference method to calculate the measured data feasible.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

324-329

Citation:

Online since:

December 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] P. Herzl, R. Dowdell: The system approach to high performance gas flow measurement with swirl meter. Flow Measurement & Control in Science & Industry. 1974, vol. 1, part 2: 132~138.

Google Scholar

[2] S.J. Bailc: Two new flowmeters have no moving parts. Control Engineering. 1969, 16(12): 73~77.

Google Scholar

[3] Dijstelbergen H: The performance of a swirl flowmeter. J. Physics E Scientific Instruments. 1970, 3: 886~888.

DOI: 10.1088/0022-3735/3/11/312

Google Scholar

[4] Furio Cascetta: Field test of as swirlmeter for gas flow measurement. Flow Measurement and Instrumentation. 1999, 10: 183~188.

DOI: 10.1016/s0955-5986(98)00047-8

Google Scholar

[5] Fu Xin, Yang Huayong: Study on mechanism of hydrodynamic oscillation in vortex precession meter using large eddy simulation. Chinese Journal of Mechanical Engineering. 2001, 14(1): 9~11.

DOI: 10.3901/cjme.2001.01.009

Google Scholar

[6] J.H. Vignos, M.C. Cheng: Adaptive filtering for a vortex flowmeter. US Patent 5576497, Nov. 1996(19).

Google Scholar

[7] Hein Richs: Measurement by a new push-pull swirlmeter. Sensors and Actuators. 1991, A(25~27): 809~813.

DOI: 10.1016/0924-4247(91)87091-g

Google Scholar

[8] Jiegang Peng, Xin Fu and Ying Chen: A Method for Removal of Fluid Pulsating Interference on Swirlmeter Based on Spectrum Phase Discrimination Using FFT. Chinese Journal of Scientific Instrument, 2004, 25(2): 217~221.

Google Scholar

[9] Jiegang Peng, Xin Fu and Ying Chen: Response of a swirlmeter to oscillatory flow. Flow Measurement and Instrumentation. 19(2008)107~115.

DOI: 10.1016/j.flowmeasinst.2007.10.002

Google Scholar

[10] Jiegang Peng, Gang Zhang: Analysis of signal characteristics of swirlmeter in oscillatory flow based on Hilbert–Huang Transform (HHT). Measurement. 45(2012)1765~1781.

DOI: 10.1016/j.measurement.2012.04.007

Google Scholar

[11] Fu Xin, Ye Peng, Song Kaichen and Yang Huayong: Development of a Novel Anti-jamming Swirlmeter. Chinese Journal of Scientific Instrument. 2000, 21 (Z1)174~177.

Google Scholar