Abstract:

Based on the experimental study of shear strengthened of reinforced concrete rectangular beam strengthened by high-strength steel wire mesh and polymer mortar , the finite element extended analysis was used. The finite element analysis software showed that with the increasing of the strand dosage and reinforcement strand length,the shear strength and stiffness of strengthened members improved . However,with the increasing of shear span ratio , the shear strength and stiffness reduced obviously .

You might also be interested in these eBooks

Info:

Periodical:

Pages:

15-19

Citation:

Online since:

December 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] NIE Jianguo, Wang Hanbing, Zhang Tianshen, etc. The Experimental study of Stainless steel wire mesh - permeability polymer mortar flexural reinforcement [J]. Journal of Building Structures, 2005, 26 (2): 1 -9.

Google Scholar

[2] Paramasivam P, Ong KCG, Lim CT E. Ferrocement Laminates for Strengthening RC T-beams[J]. Cement and Concrete Composites, 1994, 16 (2): 143-152.

DOI: 10.1016/0958-9465(94)90008-6

Google Scholar

[3] Sharma A K. Tests of Reinforced Concrete Continuous Beams with and without Ferrocement [J]. Concrete International, 1992, 22 (3): 36-40.

Google Scholar

[4] Andrews G, Sharma A K. Repaired Reinforced Concrete Beams [J]. Concrete International, 1988, 10 (4): 58-64.

Google Scholar

[5] Jiang Jianjing, Lu Xinzheng, Ye Weiping. Finite element analysis of concrete structures [M]. Beijing: Tsinghua University Press, (2005).

Google Scholar

[6] Hognestad E. Concrete Stress Distribution in Ultimate Strength Design. ACI, (1955).

Google Scholar