Optimization of Multi-Pole Permanent Magnet Synchronous Generator Based 8 Blade Magnetically Levitated Variable Pitch Low Speed Vertical Axis Wind Turbine

Article Preview

Abstract:

The paper presents a new Vertical Axis Wind Turbine (VAWT) design by using magnetic levitation (Maglev) and Permanent Magnet Synchronous Generator (PMSG). A lab prototype of VAWT was built which was run at low wind speed of around 3 to 5 meter per second. The bearing was replaced by Neodymium Magnet to avoid the friction which in turns reduces the losses and increase the efficiency. A Prototype version of PMSG was built which could generate voltage from the turbine even in low rotational speed. Suitable turbine blade angle was also determined using trial and error method.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

113-117

Citation:

Online since:

January 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Zaharim, S. K. Najid, A. M. Razali and K. Sopian Wind Speed Analysis in the East Coast of Malaysia, European Journal of Scientific Research, Vol. 32, No. 2, 2009, pp.208-215.

Google Scholar

[2] R. Bharanikumar, A. C. Yazhini and N. Kumar, Modelling and Simulation of Wind Turbine Driven Permanent magnet Generator with New MPPT Algorithm, Asian Power electronics journal, Vol. 4, (2012).

DOI: 10.1109/icpst.2008.4745264

Google Scholar

[3] W. Fei and P. I. Luk, A New Technique of Cogging Torque Suppression in Direct-Drive Permanent-Magnet Brushless Machines, IEEE Transactions on Industry Applications, Vol. 46, No. 4, 2010, pp.1332-1340. doi: 10. 1109/TIA. 2010. 2049551.

DOI: 10.1109/tia.2010.2049551

Google Scholar

[4] P. C. Krause, O. Wasynczuk and S. D. Sudho. Analysis of Electric Machinery and Drive Systems, Wiley & Sons, 2002. doi: 10. 1109/9780470544167.

DOI: 10.1109/9780470544167

Google Scholar

[5] C. V. Aravind, Rajparthiban, Rajprasad and Y. V. Wong A Novel Magnetic Levitation Assisted Vertical Axis Wind Turbine- design and Procedure, IEEE Colloquium on Signal Processing and its Applications , Melacca, Malaysia CSPA (2012).

DOI: 10.1109/cspa.2012.6194698

Google Scholar

[6] S. Belakehal, H. Benalla and A. Bentounsi, Power Maximization of Small Wind System using Permanent magnet Synchronous Generator, Revue des energies Renouvelables, Vol. 12, No. 2 , 2009, pp.307-319.

Google Scholar

[7] M. Yin, G. Y. Li, M. Zhou and C. Y. Zhao, Modeling of the Wind Turbine with a Permanent Magnet Synchronous Generator for Integration, Power Engineering Society General Meeting, 2007, pp.1-6.

DOI: 10.1109/pes.2007.385982

Google Scholar