Analysis on Thermal Economy and Peak-Shaving Capability for Combined Heat and Power (CHP) Unit in Varying Operating Conditions

Article Preview

Abstract:

Based on the principle of featured through-current area being constant, calculation model for parameters of regenerative steam extraction of CHP unit in different heating conditions is developed in this paper through using FROTRAN software. The generated output and thermal economy of the CHP unit are calculated by using the method of equivalent enthalpy drop, and the accuracy of the model is verified. With the purpose to analyze the rationality of different calculation methods, the distribution ratio of coal consumption for heat supply and coal consumption rate for power generation are calculated through method of equivalent enthalpy drop, heat quantity method and method of actual enthalpy drop under the same operating condition. Moreover, according to the operation test on the unit, the highest and lowest generated output of the CHP under various loads of heat supply are determined, which will provide a basis to the subsequent thermoelectric units in participating in peak shaving of power grid.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

508-515

Citation:

Online since:

February 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Zhenming Wang and Gang Yu: The Current Situation and Prospect of CHP in China and Some Advices [J]. Electric Power (b), 2003, 36(9): 43-49.

Google Scholar

[2] Gao Li and Lin Zhang: Analysis on the Economy of CHP [J]. Power System Engineering, 2010, 16(5): 278-280.

Google Scholar

[3] Xuedong Wang, Dong Wei, Shuyao Sun, et al: Optimized Distribution of Electric Heating Load and Peak Shaving Capacity of Various Heat Supply Units [J] Turbine Technology, 2010, 52(5): 387-390, 328.

Google Scholar

[4] Jinchang Zhang, Shaoran Wang, Guang Li, et al: Difficulties in Peak Shaving of Power Grid in Jilin Province and some Solutions [J]. Jilin Electric Power, 2004, (3): 17-19.

Google Scholar

[5] Liying Zhang, Tinglu Ye, Yaozhong Xin, et al: Relevant Problems in Large-Scale Wind Power Access to Power Grid and Measures [J]. Prodeedings of the CSEE, 2010, 30(25): 1-9.

Google Scholar

[6] Hongyu Long, Ruilin Xu, Guojun He, et al: Analysis on the Daily Peak Shaving Capacity of Thermoelectricity-Wind Power Coordinating and Dispatching System [J]. Electric Power Automation Equipment, 2013, 33(4): 30-34, 54.

Google Scholar

[7] Jianhua Chen, Wenchuan Wu, Boming Zhang, et al: Rolling Dispatching Measure for CHP Unit Accepting A Large Amount of Wind Power [J]. Automation of Electric Power Systems, 2012, 36(24): 21-27, 48.

Google Scholar

[8] Damao Xu, Debing Deng, Shiyong Wang, et al: Featured Through-Current Area of Steam Turbine and the Improvement on Flugel Formula [J]. Journal of Chinese Society of Power Engineering, 2010, 30(7): 473-477.

Google Scholar

[9] Damao Xu, Yan Ke and Shiyong Wang: General Calculation Method for Back Pressure Feature of Steam Turbine Power and its Application [J]. Journal of Engineering for Thermal Energy and Power, 2010, 25(6): 605-608.

Google Scholar

[10] Deren Sheng, Jianhong Chen, Wei Li, et al: Theoretical Analysis and Expansion of the Method of Equivalent Enthalpy Drop [J]. Journal of Zhejiang University (Engineering Science), 2004, 38(3): 347-350, 301.

Google Scholar

[11] Shenhua Hu, Haijun Zhang, Yusen Yang, et al: Application of the Method of Equivalent Enthalpy Drop in Calculating the Thermal Generation Rate of Heat Supply Unit [J]. Thermal Power Generation, 2007, (4): 11-13, 17.

Google Scholar