Numerical Analysis on the Impact of Windows and Interior Doors on Indoor Airflow of Rural Residence

Article Preview

Abstract:

There are several factors impacting on the indoor airflows, such as building openings, ambient wind speed, occupants’ behavior and so forth. This paper concentrates on the impact of windows and interior doors on airflows in a rural multi-storey residential building. The indoor airflow simulation was carried out by using the CFD software. 3 states of interior doors were set, and 60 regions were arrayed in bedroom to observe the variation of airflows. According to data of regions, the uniformity of airflow and the thermal comfort were analyzed. Simulation results identified that closing interior doors will increase the mean age of indoor air about 7 times as it under the condition of opening doors, which is from 90s to 666s. It also shows that transom windows is beneficial to improve natural ventilation efficiency, as it can raise the average wind velocity by 40% when interior doors are closed.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

1683-1688

Citation:

Online since:

April 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Qu Wanying, Ge Cuiyu: HousingScience Vol. 1(2007) p: 23-26. In Chinese.

Google Scholar

[2] Masaaki Ohba, Isaac Lun: ADVANCES IN BUILDING ENERGY RESEARCH Vol. 4(2010) p: 127-166.

Google Scholar

[3] Naghman Khan, Yuehong Su, Saffa B. Riffat: Energy and Buildings Vol. 40(2008) p: 1586–1604.

Google Scholar

[4] Valentina Fabi. Et al: Building and Environment Vol. 58(2012) p: 188-198.

Google Scholar

[5] Naghman Khan, Yuehong Su, Saffa B. et al: Energy and Buildings, Vol. 40(2008) p: 1586-1604.

Google Scholar

[6] Xiaotu Liu: Building Physics (china building industry press, Beijing 2010) In Chinese.

Google Scholar

[7] Mingjing Xie: The Study on the Natural Ventilation Design of rural Residential Houses in the North of Hunan Province: [D]. Changsha: Hunan University, 2010 In Chinese.

Google Scholar

[8] Agonafer D, Gan-Li L, Spalding D B: Application of CAE/CAD Electronic Systems, ASME, Vol. 18(1996) p: 23-26.

Google Scholar

[9] Ye X J, Zhou Z P, Lian Z W, et al: Indoor Air Vol. 16(2006) p: 320-326.

Google Scholar

[10] Fu X Z, Wu Y, Fang L X: Proceedings of National Conference on Building Physics of China, p: 326-329: 2008 In Chinese.

Google Scholar

[11] Ji Yun-zhe. et al: Journal of Lanzhou University (Natural Sciences) Vol. 2(2003) p: 96-99 In Chinese.

Google Scholar

[12] LI An-gui: Refrigeration Air Conditioning & Electric Power Machinery Vol. 2 (2004) p: 1-8 In Chinese.

Google Scholar

[13] Xiaoying Zhao: Research on the natural ventilation design of the residence in Nanjing [D]. Nanjing: Southeast University, 2005 In Chinese.

Google Scholar