CFD Investigation for Indoor Environment of a District Standard Room in Jinan City

Article Preview

Abstract:

This paper introduces the principle and characteristics of roof radiant cooling and displacement ventilation system, using numerical simulation method, the indoor airflow velocity and temperature field of the typical bedroom which uses the composite system in Ji'nan City under the different supply air velocity was calculated. The experimental results show that when the air temperature is 295.15K, to keep the indoor vertical temperature less than 3 °C, air speed should be greater than 0.1m/s and less than or equal to 0.3m/s, to provide reference for the application of roof radiant cooling and displacement ventilation system.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

1706-1711

Citation:

Online since:

April 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Wenfei Wu, Junjun Chen, Xiaotong Wang. Study of Ventilation Effects and Amenity of Multipollution Source Displacement Ventilation[J]. Environmental Engineering, Vol. 20(2002), p: 69.

Google Scholar

[2] Yanli Ren, Deying Li, Yufeng Zhang. Simulation and Analysis of the Radiant Floor Cooling and Displacement Ventilation System[J]. Journal of Shenyang Jianzhu University(Natural Science), 2008(11), p: 1066.

Google Scholar

[3] Zhongzheng Suo. Numerical Simulation of Different Kinds of Air Distribution For the Indoor Environment Quality [D]. Chongqing University, 2005, 10.

Google Scholar

[4] Qiongxiang Kong, Bingfeng Yu. Outlook for Underfloor Air Supply Systems in Office Buildings[J]. Heating Ventilating & Air Conditioning, Vol. 34(2004), p: 26.

Google Scholar

[5] Xiao Hu, Xiao-ping Miao, Liang Kong. etc. Discussion on Underfloor Air Supply Systems Technology[J]. Energy-Saving Technology. 2007(5), p: 17-21.

Google Scholar

[6] Lan Mai, Yan He. Underfloor Air Distribution System of Air Conditioning For Office Buildings[J]. Power Generation & Air Condition, 2003, (3): 31-34.

Google Scholar

[7] Wuji Zhou, Desheng Li, Jinping Zhang. The underfloor air supply technology[J]. Popular Science & Technology, 2008, (5): 93-94.

Google Scholar

[8] Ying Su, Guo-ming Shen, Jun-long Xie. Indoor Air Quality Study an Under-Floor Air-Conditioning System[J]. Power Generation & Air Condition, 2004, (1): 37-41.

Google Scholar

[9] Tao Xu, Guomin Shen, Junlong Xie. Thermal Comfort Study of an Under-Floor Air-conditioning System[J]. Power Generation & Air Condition, 2004, (4): 27-30.

Google Scholar