A Study on Sacrificial Anode Cathodic Protection for Wharf Steel Pile of Tripoli Lebanon

Article Preview

Abstract:

In this paper, the sacrificial anode protection system for steel pile of Tripoli wharf (Lebanon) was studied. Optimal average protection current densities were selected for steel pipe/sheet pile of seaside zone back filled zone and sea mud zone. Based on field test and investigation, we found that the optimal average protection current density for seaside zone is 0.060 A/m2, back filled zone 0.030 A/m2 and sea mud zone 0.025 A/m2, respectively.