The Application of Transient Electromagnetic Method in Detecting the Corrosion of Heat Distribution Pipeline

Article Preview

Abstract:

Leakage of the heat distribution pipeline will seriously affect the safety of residents and cause economic losses. This paper presents the transient electromagnetic method (TEM) for detecting the corrosion of buried heat distribution pipeline, which mainly introduced the principle of the TEM to detect the pipeline and the general detection method. Combining with an instance of corrosion detection of buried heat distribution pipeline in a certain street in China Hohhot, the detection results were analyzed and the feasibility of this method was proved through excavation. The results show that the TEM can detect the uniform corrosion distribution of buried metal pipeline and it’s effective and practical for detecting the buried heat distribution pipeline. The TEM could provide a new method for guaranteeing the safe operation of the heat distribution pipeline.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

3052-3055

Citation:

Online since:

May 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] X.H. Niu, S.H. Song and J. Wang: Monitoring System for Direct Buried Heat-supply Network. China City Gas Society, Vol. 28 (2008) No. 12, p. A12-A15.

Google Scholar

[2] Z.G. Feng and P.G. Liu: Discussion of directly buried heating pipe leakage inspection method. Guide of Sci-tech Magazine, (2012) No. 13, p.96.

Google Scholar

[3] K. Vozoff: Electromagnetic methods in applied geophysics. Geophysical surveys, Vol. 4 (1980) No. 1-2, pp.9-29.

Google Scholar

[4] M.N. Nabighian: Electromagnetic Methods in Applied Geophysics. (Society of Exploration Geophysicists, United States 1988).

Google Scholar

[5] S. Niwas and P.K. Gupta: Combined straightforward inversion of resistivity and induced polarization (time-domain) sounding data. Journal of Applied Geophysics, Vol. 75 (2011) No. 2, pp.319-326.

DOI: 10.1016/j.jappgeo.2011.06.024

Google Scholar

[6] A. Legchenko, M. Ezersky, C. Camerlynck, A. Al-Zoubi and K. Chalikakis: Joint use of TEM and MRS methods in a complex geological setting . Comptes Rendus Geoscience, Vol. 341 (2009) No. 10-11, pp.908-917.

DOI: 10.1016/j.crte.2009.07.013

Google Scholar

[7] E. Auken, A.V. Christiansen, L.H. Jacobsen and K.I. Sørensen: A resolution study of buried valleys using laterally constrained inversion of TEM data. Journal of Applied Geophysics, Vol. 65 (2008) No. 1, pp.10-20.

DOI: 10.1016/j.jappgeo.2008.03.003

Google Scholar

[8] N.O. Kozhevnikov, E.Y. Antonov, S.Y. Artamonova and A.E. Plotnikov: The geoelectric structure at the site of Crystal, underground nuclear explosion Western Yakutia from TEM data. Russian Geology and Geophysics, Vol. 53 (2012) No. 2, pp.185-193.

DOI: 10.1016/j.rgg.2011.12.015

Google Scholar

[9] A.A. Bobachev, D.K. Bolshakov, S.V. Ivanova, et al. Proceedings for the EEGS-ES* 1998 Annual Meeting (Barcelona, Spain, 1998) pp.563-566.

Google Scholar

[10] M.I. Epov, G.M. Morozova, E.Y. Antonov, et al. Method of nondestructive testing for technical state of casing strings in oil-and-gas wells basing on the transient electromagnetic method. Journal of Mining Science, Vol. 39 (2003).

DOI: 10.1023/b:jomi.0000013780.40679.8b

Google Scholar

[11] L. Pellerin and G.W. Hohmann: Transient electromagnetic inversion: A remedy for magnetotelluric static shifts. Geophysics, Vol. 55 (1990) No. 9, pp.1242-1250.

DOI: 10.1190/1.1442940

Google Scholar