Design Methods for Window Stopper Component Strength Cushions Operating under Wind Gusts

Article Preview

Abstract:

An evaluation of the impact forces imparted due to wind flow onto and across walls is necessary to improve the safety of stopper components in swing-type windows. A strong wind test was performed to measure the impact force imparted by wind, and the characteristics of the wind energy and resulting impact force were clarified. An impact force evaluation method based on a simple mechanical model was proposed. Furthermore, it was confirmed that the deformation of a plastic stopper component due to an impact force could be modeled via an empirical linear formula, derived experimentally using the impact force imparted in a drop weight load test. The proposed evaluation method is considered to be useful for the safety design of swing-type windows.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

486-492

Citation:

Online since:

June 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] H. Arakawa, Y. Matumoto, and S. Suematu,: A study on the impact resistance of vertically pivoted window, Summaries of technical papers of Annual Meeting Architectural Institute of Japan (1988), pp.195-196. (in Japanese).

Google Scholar

[2] N. Minami, K. Kuroki and N. Wada and K. Yamazaki, : Experimental study of a test method for wind gusts (impact) on opening windows, Part 1: Summaries of technical papers of the Annual Meeting Architectural Institute of Japan (2004).

Google Scholar

[3] N. Wada, K. Kuroki and T. Minami and K. Yamazaki, : Experimental study of the test method on gust of wind (impact) of opening windows, Part 2: Experiment and study regarding correlations for the test method for wind gusts for wind and weight, Summaries of technical papers of the Annual Meeting Architectural Institute of Japan, (2004).

Google Scholar

[4] N. Wada, : Experimental study of the test method on gust of wind (impact) of opening windows, Japan Testing Center for Construction Materials Journal Vol. 44 (2008), pp.14-19(in Japanese).

Google Scholar

[5] G. Nishie,. and T. Mori, : Evaluation of Impact force Caused by Wind Flowing along a Wall in the Stopper Components of Swing-type Windows, Journal of Wind Engineering, JAWE Vol. 37, No. 3 (No. 132)(2012), pp.67-77. (in Japanese).

DOI: 10.5359/jwe.37.67

Google Scholar