Islanding and Non-Islanding Detection for Grid Connected Distribution System

Article Preview

Abstract:

In this paper, wavelet transform based approach is proposed for islanding detection in a distribution system. The negative sequence voltage and negative sequence current obtained due to disturbances are measured at the point of common coupling (PCC) and given to the wavelet processing module to extract features like standard deviation and energy content. The negative sequence voltage and current components are decomposed under various levels to filter out lower frequency components. From the obtained features suitable threshold value is fixed for classifying the islanding and non-islanding events.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

696-701

Citation:

Online since:

June 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] P.K. Dash, T.K. Malhar Padhee, R. A Panigrahi, A hybrid time-frequency approach based fuzzy logic system for power island detection in grid connected distributed generation, J. Electr Power Energ Syst. 42 (2012) 453-464.

DOI: 10.1016/j.ijepes.2012.04.003

Google Scholar

[2] N.W.A. Lidula, A.D. Rajapakse, A pattern recognition approach for detecting power islands using transient signals—Part I: design and implementation, IEEE Trans Power Deliv. 25 (2010) 3070-3077.

DOI: 10.1109/tpwrd.2010.2053724

Google Scholar

[3] A. Samui, S.R. Samantaray, Assessment of ROCPAD relay for islanding detection in distributed generation, IEEE Trans Smart Grid. 2 (2011) 391-398.

DOI: 10.1109/tsg.2011.2125804

Google Scholar

[4] A.H.K. Alaboudy, H.H. Zeineldin, Islanding detection for inverter-based DG coupled with frequency-dependent static loads, IEEE Trans Power Deliv. 26 (2011) 1053-1063.

DOI: 10.1109/tpwrd.2010.2087042

Google Scholar

[5] H. Mohamad, H. Mokhlis, A review on islanding operation and control for distribution network connected with small hydro power plant, Renew Sustain Energy Rev. 15 (2011) 3952-3962.

DOI: 10.1016/j.rser.2011.06.010

Google Scholar

[6] P.K. Ray, S.R. Mohanty, N. Kishor, Disturbance detection in grid-connected distributed generation system using wavelet and S-transform, Electr Power Syst Res. 3 (2011) 805-819.

DOI: 10.1016/j.epsr.2010.11.011

Google Scholar

[7] P. Mahat, Z. Chen, B. Bak-Jesen, A hybrid islanding detection technique using average rate of voltage change and real power shift, IEEE Trans Power Deliv. 84(2009) 1318-1326.

DOI: 10.1109/pes.2009.5275976

Google Scholar

[8] C.T. Hsieh, J.M. Lin, S.J. Huang, Enhancement of islanding-detection of distributed generation systems via wavelet transform-based approaches , Int J Electr Power Energ Syst. 10 (2008) 575-580.

DOI: 10.1016/j.ijepes.2008.08.006

Google Scholar