Study on Fire Smoke Movement of Urban Traffic Link Tunnel

Article Preview

Abstract:

Fire simulation software (FDS) was employed to simulate the fire smoke movement of urban traffic link tunnel (UTLT) under the semi-transverse ventilation. Numerical simulation and theoretical analysis were used to analyze the fire smoke movement in three fire scenarios. The analytical results show that: semi-transverse ventilation can effectively control the spread of fire smoke. When the exhaust air rate is certain, the exhaust port interval of 20 m and 50 m has little effect on function of smoke control. The research results provide references for the design of smoke control measures in UTLT.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

1037-1041

Citation:

Online since:

July 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Gaoying Hua, Wei Wang, Yaohu Zhao a, et al: Building Science Vol. 24 (2008), p.15.

Google Scholar

[2] Jie Zhu, Junyu Dai, Jianbo Wu, et al: Journal of Safety and Environment Vol. 13 (2013), p.240.

Google Scholar

[3] Zhigang Zhang: Southwest Jiaotong University Master Degree Thesis. (2013).

Google Scholar

[4] C. Lin, Y.K. Chuah: Tunnelling and Underground Space Technology Vol. 23 (2008), p.522.

Google Scholar

[5] Yuchun Zhang, Chuan He, Yanhua Zeng, et al: Journal of Disaster Prevention and Mitigation Engineering Vol. 29 (2009), p.663.

Google Scholar

[6] Lei Li, Wenli Liu, Hai Tang, Wandi Wang: Science & Technology Review Vol. 26 (2008), p.40.

Google Scholar

[7] PRC Ministry of Construction: Code of Design on Building Fire protection and prevention (China Planning Press, Beijing 2006).

Google Scholar